MC PMRL
Mobile Radio Router
MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany
Tel: +49 511 67 69 99-0, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net
14
8 Ports
and GPIO’s
8.1 Ethernet-Interfaces (All)
Port
Signal
Description
1
TD+
Transmit plus
2
TD-
Transmit minus
3
RD+
receive plus
4
No function
Internal 100nF against GND
5
No function
Internal 100nF against GND
6
RD-
Receive minus
7
nc
8
Shield
Internal shielding
LED
yellow
SPEED
1 Blinks: Led Blinks once = 10Base link
2 Blinks: Led Blinks twice = 100Base link
LED green
ENWAYEN
ON: Network link has been established
Blinking: Network activity has been detected
8.2 Power supply
Connection to an AC power supply must be made by using a suitable power supply unit.
The DC voltage must be between 8 and 30V.
Port
Description
POW -
Power supply, negative connection
POW +
Power supply, positive connection