2.

 

If you cannot establish a connection, make sure the device is using 
the default configuration by following the 

Restoring factory default 

network settings

 procedure below. 

Once a connection and communication is established, you can change 
the configuration for other network scenarios. InstaCal is required to 
install and configure the E-1608 on Windows platforms. 

Restoring factory default network settings  

To reset the network configuration settings to the factory default values, 
complete the following steps:  

1.

 

Remove power from the device.  

2.

 

Press and hold the 

Factory reset 

button while re-applying power. 

Hold the button for at least four seconds until the 

Power 

and 

Activity 

LEDs blink to indicate that the factory settings have been restored.  

3.

 

Refer to Figure 1 for the location of the 

Factory reset 

button and 

Power 

and 

Activity 

LEDs. 

4.

 

Release the button so the device continues startup with the default 
settings. If the button is released before the two LEDs blink, the 
settings are not affected and the device starts up normally.  

If InstaCal is open when default settings are restored, click the 

Refresh 

Boards 

button on the InstaCal toolbar to reflect the changes  

 

1  Factory reset button 

2  Power LED (top) and Activity LED (bottom) 

3  Link/activity LED (left) and speed LED (right) 

4  External power connector 

Figure 1. E-1608 LEDs, buttons, and connectors

Distributed by MicroDAQ.com, Ltd.               www.MicroDAQ.com               (603) 746-5524

Summary of Contents for E-1608

Page 1: ...ation Refer to the Quick Start that ships with your device for instructions on installing the other software available on the MCC DAQ CD Select Android Examples to install example projects on Windows platforms to deploy and run on an Android device Refer to the UL for Android Example Projects help topic in the UL for Android help files to learn how to deploy and run example projects on an Android ...

Page 2: ...ure that you connect to a local network with DHCP enabled If you do not have access to a local network or DHCP is not enabled on that network use a direct connection to a Windows PC It may take a minute or two to detect the device and assign the address The green Link activity LED turns on when there is a valid Ethernet link and blinks when network activity is detected Once the E 1608 is physicall...

Page 3: ...plying power Hold the button for at least four seconds until the Power and Activity LEDs blink to indicate that the factory settings have been restored 3 Refer to Figure 1 for the location of the Factory reset button and Power and Activity LEDs 4 Release the button so the device continues startup with the default settings If the button is released before the two LEDs blink the settings are not aff...

Page 4: ...of these settings Address mode settings The address mode settings determine whether the default IP address subnet mask and gateway settings are assigned to the E 1608 or an auto addressing method is used to assign these settings IP address settings The default IP address settings are assigned to the E 1608 when automatic addressing is disabled or not available DHCP or Link Local for example Defaul...

Reviews: