McAfee® Network Security Platform 6.0
System Fault Messages
64
Fault
Severity
Description/Cause
Action
Sensor is not
initialized
Warning
The Sensor is not properly
initialized. Either it is in the
process of starting up and is
not ready, or the signature
set is missing on the Sensor.
The Sensor may have just been
rebooted and is not up yet. Wait
a few minutes to see if this is the
issue; if not, check to ensure that
a signature set is present on the
Sensor. A
resetconfig
command may have been
issued, and the Sensor not yet
been reconfigured.
Sensor
Performance
<Metric Name>
Warning
<Metric Name> has
<risen/fallen> to <%/count>
on
<Sensor name / Port name>,
which is <above/below> the
configured <Band Name>
threshold of <%/count>. For
example: <CPU utilization
metric> has <risen> to
<70%> on <Sensor name>
which is <above> the
configured <alarm band
value> threshold of <60%>,
then this type of warning will
be generated.
Check NSP operation to bring
down the metrics below
configured threshold level.
up
Warning
The Sensor has just
completed booting and is on-
line.
This message is informational.
Acknowledge the fault.
SSL decryption
keys out of sync
Warning
The Manager was unable to
update the decryption key on
one Sensor in a failover pair,
causing the key on one
Sensor to be out of sync with
the one on its failover peer
The Manager will make another
attempt to update the key.
Ensure that the Sensor is online
and in good health.
The fault will clear when the
Manager successfully pushes
the key to the Sensor and both
keys are in sync.
System startup in
progress; alerts
being restored
Warning
System startup restored
alerts from the archive file.
Threat Analyzer may not
show all alerts.
Threat Analyzer may not show
all alerts.