29
V4 PROPORTIONAL CONTROLS
POWER ON / OFF (Emergency Stop)
Rotate Clockwise to Power On – control unit will emit a single beep and screen will display
the selected PTO speed, software version and the McConnel name. Press to Power Off.
ROTOR START – Uphill Cutting
This button starts the rotor for ‘uphill’ cutting – when
the button is pressed the control unit will emit a
single beep, the LED light will illuminate and the
screen will momentarily display
‘FLAIL START
9
’.
ROTOR START – Downhill Cutting
This button starts the rotor for ‘downhill’ cutting –
when the button is pressed the control unit will emit a
single beep, the LED light will illuminate and the
screen will momentarily display ‘FLAIL START
9
’.
ROTOR STOP
This button stops the rotor – when the button is
pressed the control unit will emit a single beep and
the screen will momentarily display ‘FLAIL STOP
9
’
– the LED lights above both rotor start buttons will be
illuminated for approximately 10 seconds, during this
period the rotor start buttons will be disabled to allow
sufficient time for the rotor to power down. When the
LED lights go out the rotor direction can be changed
or the rotor allowed to stop.
WARNING: The LED lights going out do not
indicate that the rotor has stopped rotating, it
signifies only that the oil flow to the rotor has ceased sufficient for the direction of rotation
to be changed - therefore when stopping a rotor it must be noted that it will continue to
freewheel for a considerable length of time after the stop button has been activated, in
some case this can be up to 40 seconds.