5
Step: E
Connecting the Control Box to the Upper Shaft:
1.Place the detector on a flat surface,with the handle facing upwards.
2.Position the armrest on top of the control box.
3.Clip the control box onto the armrest,ensuring the battery plug faces away from the
coil.
4.Fasten with the wing-nuts.
5.Wind the Quick-Trak button cable around the upper shaft and plug it into the Smart
Point socket in the control box.Ensure that the cable is wrapped firmly but avoid
strain on the connector.
Step: F
Connecting the Coil Cable:
1.Wind the coil cable around the lower and upper shafts enough times
to take up the slack.Leave enough slack at the bottom of the cable near
the coil to allow the angle of the coil to be adjusted while detecting.
2.Use the velcro straps to secure the coil cable to the shaft.
3.Plug the coil connector into the coil socket on the control box.firmly
tightening the retaining ring to hold it in place.