conductive pollution which could become conductive due to condensation. Failure to maintain these minimum distances would invalidate
the approval.
4) The analogue telecommunications interface is intended to be connected to telecommunication network voltage (TNV) circuits which
may carry dangerous voltages. The telephone cord(s) must be disconnected from the telecommunications system until the card has been
installed within a host which provides the necessary protection of the operator. If it is subsequently desired to open the host equipment for
any reason, the telephone cord(s) must be disconnected prior to effecting access to any internal parts which may carry
telecommunication network voltages.
Table:
Clearance (mm)
Creepage (mm)
Voltage Used or Generated by
X
Y
Host or Other Cards
2.0
2.4 (3.8)
Up To 50 Vrms or Vdc
2.6
3.0 (4.8)
Up To 125 Vrms or Vdc
4.0
5.0 (8.0)
Up To 250 Vrms or Vdc
4.0
6.4 (10.0)
Up To 300 Vrms or Vdc
For a host or other expansion card fitted in the host, using or generating voltages
greater than 300V (rms or dc), advice from a competent telecommunication
safety engineer must be obtained before installation or relevant equipment
Above 300 Vrms or Vdc
Host:
Power Supply Unit
or other source of
excessive voltage
TLR or TLR+ or
Exprecium card
Expansion
Card
X
X
Y
Y