HEBT-3V BUN TOASTER
14
P/N 1011377 Rev. G 07/17
McDonald’s
TROUBLESHOOTING
Problem
Possible Cause
Corrective Action
Control Display flashes
Err 5
continuously. Buns
not toasting properly.
The A Platen temperature has not
reached the setpoint temperature
within 20 minutes.
Allow the unit to warm up for 30 minutes and then
recheck. If the Control Display still flashes
Err
5
, contact your maintenance person or Antunes
Technical Service for service.
Failed A Platen Thermocouple.
Contact your maintenance person or Antunes
Technical Service for service.
Failed Control Board
Control Display flashes
Err14
continuously.
Buns not toasting prop-
erly.
The B Platen temperature has not
reached the setpoint temperature
within 20 minutes.
Allow the unit to warm up for 30 minutes and
then recheck. If the Control Display still reads
Err
14
, contact your maintenance person or Antunes
Technical Service for service.
Failed Rear Platen Thermocouple.
Contact your maintenance person or Antunes
Technical Service for service.
Failed Control Board.
Control Display flashes
Err 9
continuously.
Control Compartment ambient tem-
perature is above 150
°
F (66
°
C)
Verify side vents on toaster are unblocked and not
near other heating appliances. If problem persists,
contact your maintenance person or Antunes
Technical Service for service.
Failed Cooling Fan.
Failed Control Board
Control Display Flashes
Err 19
continuously.
Buns Burn.
Failed A Platen Solid State Relay.
Contact your maintenance person or Antunes
Technical Service for service.
Failed Control Board.
Failed A Platen Thermocouple.
Control Display flashes
Err 18
continuously.
Buns Burn.
Failed B Platen Solid State Relay.
Contact your maintenance person or Antunes
Technical Service for service.
Failed Control Board.
Failed B Platen Thermocouple.
Control Display flashes
Err 13
continuously.
Buns not toasting prop-
erly.
Loose A Platen Thermocouple con-
nection on Control Board or the
Front Platen Thermocouple is open.
Re-secure the A Platen Thermocouple to the
Control Board. If the Control Display still reads
Er 13
, check the front Thermocouple for continu-
ity. Contact your maintenance person or Antunes
Technical Service for service.
Failed Control Board.
Control Display flashes
Err 11
continuously.
Buns not toasting prop-
erly.
Loose B Platen Thermocouple con-
nection on Control Board or the
Rear Platen thermocouple is open.
Re-secure the B Platen Thermocouple connection
to the Control Board. If the Control Display still
reads
Er 11
, check the Rear Thermocouple for
continuity. Contact your maintenance person or
Antunes Technical Service for service.
Failed Control Board.
Control Display flashes
Err 12
continuously.
Buns not toasting prop-
erly.
Shorted A Platen Thermocouple to
ground.
Disconnect and re-secure the A Platen
Thermocouple connection to the Control Board.
If the Control Display still reads
Er 12
, check the
Rear Thermocouple for continuity. Contact your
maintenance person or Antunes Technical Service
for service.
Failed Control Board
Control Display Flashes
Err 10
continuously.
Buns not toasting.
Shorted B Platen Thermocouple to
ground.
Re-secure the B Platen Thermocouple connection
to the Control Board. If the Control Display still
reads
Er 10
, check the Rear Thermocouple for
continuity. Contact your maintenance person or
Antunes Technical Service for service.
Failed Control Board.
Summary of Contents for 9210859
Page 24: ...HEBT 3V BUN TOASTER 24 P N 1011377 Rev G 07 17 McDonald s WIRING DIAGRAM...
Page 25: ...HEBT 3V BUN TOASTER 25 P N 1011377 Rev G 07 17 McDonald s NOTES...
Page 26: ...HEBT 3V BUN TOASTER 26 P N 1011377 Rev G 07 17 McDonald s NOTES...
Page 27: ...HEBT 3V BUN TOASTER 27 P N 1011377 Rev G 07 17 McDonald s NOTES...
Page 28: ...1 630 784 1000 1 800 253 2991 1 630 784 1650 86 512 6841 3907 86 512 6841 3637...