Closing/Sanitation Procedures
© 2004 -2018 The Coca-Cola Company, Cornelius and
McDonald’s Corporation. All Rights Reserved.
42
Clean Drip Tray & Exterior Surfaces
Clean drip tray and all exterior surfaces with
warm soapy solution and rinse with clean
potable water.
Pour warm (NOT HOT) water down the drip
tray drain to flush drain line.
Inspect water deflector after cleaning to
check for proper installation.
Reinstall Cup Rest
The cup rest must be installed with the oval
rails up and the “Cup Positioning Bracket”
must be at the rear of the drip tray.
The cup positioning bracket, located on the
cup rest, contains a spring that is positioned
so it touches the cup in the cup holder as the
cup moves past the spring. This moves the
cup to the rear (based on the direction of
movement) of the cup holder. This insures
that all cups will be in the same position
regardless of its size.
Reinstall Conveyor
Align the drive pin on the left side of the con-
veyor assembly so that the conveyor seats
properly. The conveyor drive pin must
engage the drive socket on the gear box.
When installing the conveyor, it may be nec-
essary to move the conveyor manually to
allow the drive pin to insert into the drive
socket.
Tighten the thumb screws on the cover.