Maintenance
Clean Heater Surfaces
The heater faces must be kept clean and free of any plastic build up or
contamination.
Before each fusion joint the heater surfaces must be wiped with a clean,
non-synthetic cloth.
NOTICE:
Do not use an abrasive pad or steel wool. Use a non-synthetic
cloth that won't damage surfaces.
TX00440-8-14-08
PH
03
87
5-
4-15-0
9
6 - 4
Installing Butt Fusion Heater Plates
The heater body of this assembly is not coated. Coated butt fusion
heater plates are available for all butt fusion applications.
Butt fusion heater plates are installed with eight Stainless Steel
Cap Screws.
Care should be taken to assure that the butt fusion heater plates
are seated on the heater body, and that there is no foreign matter
trapped between these surfaces.
IMPORTANT:
Do not over tighten the bolts.
The surface of the butt fusion heater plates are coated with an
antistick coating.
TX02311-07-30-04
Adjusting Heater Temperature
Turn knob to desired temperature. Measure the heater surface
temperature with a pyrometer. Any variance must be corrected to the
pyrometer reading.
Loosen setscrew in the knob. Turn knob to point to the same
temperature as the pyrometer. Tighten setscrew in the knob.
Turn knob to desired temperature. Allow heater to stabilize at the new
temperature (5 to 10 minutes) after adjusting.
The thermometer on the heater body indicates internal temperature and
should be used as a reference only.
TX02009-3-13-02
PH
03
87
6-
4-15-0
9
PH
02
313-
4-
24
-0
2
Summary of Contents for DynaMc 250HP