Set Up Calibration (continued)
Insert the Set Up Gauge using the fitting side heater stop gauge
and adjust short heater stop bolt until the bolt touches the gauge
(from the heater stop mount) in both locations.
Tighten the set screws to lock the bolts in position.
Loosen the set screws for the long heater stop bolts.
Insert the Set Up Gauge using the pipe side heater stop gauge and
adjust long heater stop bolts until the bolt touches the gauge (from
the heater stop mount) in both locations.
Tighten the set screws to lock the bolts in position.
CD0
14
27-1
1-2
0-1
5
CD0
14
28-1
1-2
0-1
5
CD0
14
29-1
1-2
0-1
5
Set Up
3 - 4
Set Up Gauge
Short Heater
Stop Bolt
Long Heater
Stop Bolt
Set Up Gauge