Heating the Pipe
A) Move the carriage to the left, bringing the heater into
contact with both pipe ends.
B) Move selector valve to center position once contact is
established.
C) If heating pressure is not required, allow the pressure to
stabilize at the lowest setting and return carriage control
valve to neutral position.
TX00874-11-8-00
Inserting Heater
Heater Is Not Explosion Proof. This unit is not
explosion proof. Operation of heater in a
hazardous environment without necessary safety
precautions will result in explosion and death.
If operating in a hazardous environment, heater
should be brought up to temperature in a safe
environment, then unplugged before entering the
hazardous atmosphere for fusion.
Use a clean non-synthetic cloth to clean the butt fusion heater
adapter surfaces.
Verify heater temperature by noting the reading on the dial
thermometer.
Insert heater between the pipe ends.
TX00377-9-15-94
Operation
PH02333-7-08-02
3 - 7