Maintenance
Installing Butt Fusion Heater Adapters
The heater body of this assembly is not coated. Coated butt
fusion heater plates are available for all butt fusion applications.
Butt fusion heater adapters are installed with Stainless Steel Cap
Screws.
Care should be taken to assure that the butt fusion heater
adapters are seated on the heater body, and that there is no
foreign matter trapped between these surfaces.
IMPORTANT:
Do not over tighten the bolts.
The surface of the butt fusion heater adapters are coated with an
antistick coating.
TX01899-11-15-00
Adjusting Heater Temperature
Turn knob to desired temperature. Measure the heater surface
temperature with a pyrometer. Any variance must be corrected
to the pyrometer reading.
Loosen setscrew in the knob. Turn knob to point to the same
temperature as the pyrometer. Tighten setscrew in the knob.
Turn knob to desired temperature. Allow heater to stabilize at
the new temperature (5 to 10 minutes) after adjusting.
The thermometer on the heater body indicates internal
temperature and should be used as a reference only.
TX02034-7-08-02
PH02333-7-08-02
PH02313-7-08-02
7 - 8
Heater Indicator Light
The heater has a red indicator light on the handle at the bottom
of the temperature scale. When the heater is plugged in and
preheating the light glows steadily until the set temperature is
reached. The light then goes off and on slowly as the heater
maintains temperature.
If the heater is not operating properly, the control will attempt
to turn the heater off and the indicator light will flash rapidly.
If this occurs, disconnect the power and take it to a McElroy
Authorized Service Center for repair.
TX02035-7-08-02
PH02314-7-08-02
PREHEATING
INDICATOR LIGHT
AT SET POINT
ERROR
PH00482-8-16-95
Summary of Contents for TracStar 28