Operation
3 - 8
Check Heater Temperature
NOTICE:
Incorrect heating temperature can result in
questionable fusion joints. Check heater plates
periodically with a pyrometer and make necessary
adjustments.
Check heater surface temperature.
Refer to the pipe manufacturer's recommendations or appropriate
joining standard for proper heater temperature.
TX04536-10-24-12
WR000
77
-4
-16
-9
3
Inserting Heater
Heater is not explosion proof. This unit is not
explosion proof. Operation of heater in an
explosive atmosphere without necessary safety
precautions will result in serious injury or death.
If operating in an explosive atmosphere, heater
should be brought up to temperature in a safe
environment, then unplugged before entering the
explosive atmosphere for fusion.
Use a clean non-synthetic cloth to clean the butt fusion heater plate
surfaces.
Verify heater temperature by noting the reading on the dial
thermometer.
Insert heater between the pipe ends.