11.2 Dispenser height
The plastic film needs to be applied around the centre of the bale, to ensure optimum
coverage. The dispenser may need to be adjusted up or down, as necessary.
1.
Ensure the machine is securely chocked and the dispenser is well supported
2.
Loosen the 4
x M16 nyloc nuts on the U-bolts, but do not remove!
3.
Slide the dispenser up or down, as required
4.
Tighten the 4 x M16 nyloc nuts
5.
Remove the support and chocks
Figure 11.b - Dispenser height adjustment
11.3 Table stop position magnet (Program R94
load position - 995 LSR & TSR)
If the table does not stop in the correct position in line with the chassis, it is possible to
move the magnet that controls the stop position. However, it must be checked first that
the machine is operating at the correct speed, has a bale on the table and the plastic
film is attached, as all of these factors will have a bearing on where the machine stops
(See Section 15.1.1 in “Trouble Shooting” on page 73).
The magnet may be adjusted as follows:
1.
Tip up the table and fit the safety bar
2.
Identify the magnet to be changed. There are two sets of magnets near the
outside of the table. The magnets that require adjusting are positioned at the
table end.
3.
Loosen the M6 bolt and nyloc nut holding the magnets in position
4.
If the table does not turn far enough, push the magnets in the direction shown
5.
If the table turns too far, push the magnets in the direction shown
6.
Tighten the M6 bolt and nyloc nut (Do not overtighten as the magnets may
crack or shatter)
7.
Remove the table safety bar and lower the table back down
8.
Test the machine in automatic mode to see if it is stopping correctly, if not re-
adjust