background image

GROUND LINER

®

ETL

Installation Instrucions

Designplan Lighting, Inc., 79 Trenton Ave., Frenchtown NJ, 08825.  T.908-996-7710  F.908-996-7042

Summary of Contents for Designplan 7101121/C02

Page 1: ...GROUND LINER ETL Installation Instrucions Designplan Lighting Inc 79 Trenton Ave Frenchtown NJ 08825 T 908 996 7710 F 908 996 7042...

Page 2: ...INDEX 3 4 5 6 9 13 14 15 17...

Page 3: ...23 C22 Ground Liner 500 x 33 mm Opal blue 7101123 C09 Ground Liner 500 x 33 mm Opal RGB 7101123 C11 Ground Liner 250 x 33 mm Opal white 7101124 C02 Ground Liner 250 x 33 mm Opal warm white 7101124 C22...

Page 4: ...Housing 20 micras aluminium Recessed box Pressure load 30 kN Protection class IP66 68 Impact resistance IK10 Temperature range 30 C a 70 C 22 F to 158 F Recessed box included ELECTRICAL SPECIFICATION...

Page 5: ...dy 1000 500 250 mm 39 4 19 7 9 85 in 35 mm 1 38 in 75 mm 2 95 in 125 mm 4 92 in 30 mm 1 18 in 1000 500 250 mm 39 4 19 7 9 85 in 43 mm 1 69 in 1000 500 250 mm 39 4 19 7 9 85 in 35 mm 1 38 in 75 mm 2 95...

Page 6: ...of installed product Do not take out the foam joint stuck to the box it is needed to absorb possible material expansions For concrete installation shoETLd be used a covering over the concrete in order...

Page 7: ...Ground Liner ETL TECHNICAL GUIDE 1 1 2 3 Place it to avoid entrance of dirt NOT INCLUDED GROUND LINER ETL INSTALLATION...

Page 8: ...Ground Liner ETL TECHNICAL GUIDE 1 2 3 GROUND LINER ETL INSTALLATION...

Page 9: ...Ground Liner ETL TECHNICAL GUIDE Pour the concrete carefully around the luminaires Remove cover GROUND LINER ETL INSTALLATION...

Page 10: ...IMT 152 V1 11 Ground Liner ETL TECHNICAL GUIDE Concrete detail Luminaire position Luminaire place 5mm FILL UP WITH CONCRETE UP TO 5mm OVER THE BOX LEVEL 20 cm MINIMUM DRAINAGE GROUND LINER ETL INSTALL...

Page 11: ...Ground Liner ETL TECHNICAL GUIDE Once the luminaire has been placed the lateral sides must be sealed with BOSTIK POLIURETANE for OUTDOOR applications GROUND LINER ETL INSTALLATION...

Page 12: ...GLETL IMT 152 V1 13 Ground Liner ETL TECHNICAL GUIDE Next Luminaire Next Luminaire GROUND LINER ETL INSTALLATION...

Page 13: ...Ground Liner ETL TECHNICAL GUIDE Centric extraction End extraction GROUND LINER ETL EXTRACTION TOOL...

Page 14: ...eters from controller to first luminaire Maximum 100 meters from amplifier to last luminaire Maximum 5 luminaires of 1m per DMX controller with PSU 24V DC 150W Maximum 100 meters from controller to fi...

Page 15: ...supply to first luminaire M030360 Maximum 5 luminaires of 1 meter each line connected with PSU 24V DC 320W 15m Maximum 5 meters from power supply to first luminaire POWER CONTROL 3 2 Line 2 3 Line 2 3...

Page 16: ...rive 720D DMX DALI 0 10V 24V DC Power Supply 24 V DC 320 W Next line 24V DC PWM Blue GND Black 24 White 24 Brown LINEARdrive 720D Group 1 GND 1 GND 2 GND 3 GND 4 DMX DMX DMX shield LEDSync Dali IN Dal...

Page 17: ...e the conformity of the whole system and declare it by attaching the CE sign Installation place Make sure that the product is mounted on a stable even and tilt fixed background Note the minimum distan...

Page 18: ...IMT 152 v 01 Ground Liner ETL Designplan Lighting Inc 79 Trenton Ave Frenchtown NJ 08825 T 908 996 7710 F 908 996 7042...

Reviews: