background image

*Line Grazer® 300 230V only suitable for end of the line.

** Medidas para Line Grazer® 230V 600.  

*Line Grazer® 300 230V sólo para final de línea.

 

 

** Measures for Line Grazer® 230V 600.

Line Grazer 230V 600 / 900 / 1200 mm.

Line Grazer 230V 300 mm.*

323 mm.

(12,7 in)

190 mm.

(4,29 in)

109,5 mm.

(4,31 in)

76,5 mm.

(3,01 in)

76,5 mm.

(3,01 in)

625** / 933-1235 mm.

(24,6** / 36,7-48,6 in)

190** / 400 mm.

(4,29** / 15,75 in)

109,5** / 300 mm.

(4,31** / 11,81 in)

Soporte centro alto

Tall central bracket

72 mm.

(2,83 in)

110 mm.

(4,33 in)

Soporte centro bajo

Small central bracket

72 mm.

(2,83 in)

90 mm.

(3,54 in)

Soporte standard  

Standard bracket

72 mm.

(2,83 in)

111,6 mm.

(4,39 in)

LG.IMT-118.v8.

6.

LINE GRAZER® 230V

3. DIMENSIONS / 

MEDIDAS

 

Line Grazer

® 

230V

 

 

TECHNICAL GUIDE

Las imágenes son ilustrativas. -  These images are illustrative. 

Summary of Contents for Line Grazer 1200

Page 1: ...LINE GRAZER 230V Installation Instructions v 08 Manual Instalaci n...

Page 2: ......

Page 3: ...E PRODUCTO 4 2 TECHNICAL DATA DATOS TECNICOS 5 3 DIMENSIONS MEDIDAS 6 4 INSTALLATION INSTALACI N 7 5 CONNECTION CONEXIONADO 8 6 ANNEX INSTALLATION LG RECESSED BOX ANEXO INSTALACI N LG RECESSED BOX 10...

Page 4: ...ITUD 1 300 mm 2 600 mm 3 900 mm 4 1200 mm FINISHES ACABADOS 0 Silver Plata 2 Black Negro 3 White Blanco TYPE MODELO 0 48 LEDs 1 2 m pitch 25 mm 1 36 LEDs 1 2 m pitch 33 mm CONTROL CONTROL on off DMX 5...

Page 5: ...sures with standard bracket ESPECIFICACIONES EL CTRICAS ELECTRICAL SPECIFICATIONS Voltaje de entrada Input voltage 100 277V AC Clase protecci n Protection class I Tipo control Control type DMX512 A on...

Page 6: ...n 76 5 mm 3 01 in 76 5 mm 3 01 in 625 933 1235 mm 24 6 36 7 48 6 in 190 400 mm 4 29 15 75 in 109 5 300 mm 4 31 11 81 in Soporte centro alto Tall central bracket 72 mm 2 83 in 110 mm 4 33 in Soporte ce...

Page 7: ...fijar Set up angle and fix the bracket Conexi n Connection Soporte standard Standard bracket A Soporte centro alto centro bajo Tall central Small central bracket B Est ndar Standard 110 Centro bajo S...

Page 8: ...Line Grazer Ref M030585 L 1 5m Ref See interconnection measures table Ver tabla de medidas de interconexi n End cap Tap n final MORE THAN 15 LINE GRAZER WITH DMX PARA M S DE 15 LINE GRAZER CON DMX UP...

Page 9: ...22mm2 Marr n Brown Azul Blue Amarillo Verde Ground Blanco White Malla Shield Naranja Orange 230V AC DMX DALI SIGNAL LG IMT 118 v8 9 LINE GRAZER 230V 5 CONNECTION CONEXIONADO Line Grazer 230V TECHNICAL...

Page 10: ...box 7501095 til extracci n en l nea Centric extraction tool 7101196 1 76 mm 2 99 in 323 625 1235 mm 12 7 24 6 48 6 in 143 mm 5 63 in 125 mm 4 92 in 1 PLANOS DRAWINGS Medidas en mm pulgadas Measures i...

Page 11: ...crete Colocar la luminaria Place de luminaire Kit uni n Fixation kit til extracci n Extraction tool End extraction Extracci n en linea Centric extraction LG IMT 118 v8 11 LINE GRAZER 230V 6 ANNEX INST...

Page 12: ...V TECHNICAL GUIDE Detalle hormigonado Concrete detail Posici n luminaria Luminaire position Colocaci n luminaria Luminaire place 5mm HORMIGONAR 5mm POR ENCIMA DEL CAJET N FILL UP WITH CONCRETE UP TO 5...

Page 13: ...ubrimiento del hormig n para as mejorar la protecci n contra agentes qu micos externo For concrete installation should be used a covering over the concrete in order to improve the protec tion against...

Page 14: ...ical shock may occur Installation The complete installation must be done by an electrical expert or a specialized maintenance team who is familiar with valid directives Attention Use only parts which...

Page 15: ...a para el electricista Si no instala un sistema suministrado de forma completa es decir con el transformador actuar como el fabricante en el sentido de las directivas de baja tensi n En este caso le i...

Page 16: ...LINE GRAZER 230V IMT 118 v 08 C dels Oficis n 25 Pol Ind el Reg s 08850 Gav Barcelona SPAIN T 34 93 630 28 00 F 34 93 630 29 66 M info mcilight com mcilight com by...

Reviews: