KP03 Mini Apartment Compactor
SERVICE
65
Copyright
©
7/2021 K-PAC
™
Compactors, a product of McLaughlin Family Companies
All Rights Reserved
100% CNT MENU
- The 100% CNT
func-
tion controls at what point the 100% light comes On. The
default setting is set at six
, which means
that after a total of six signals are received from the 100%
LIT MENU, the 100% light will be triggered to come On.
To reset the 100% light after it has come On, depress the
Emergency Stop. After depressing, pull Up again to
resume normal operation.
Figure 41
100% LIT MENU
(Figure 42, 1)
menu is
the timer that controls the time required before a signal is
sent to the 100% CNT. It’s default setting is 6.05 seconds
. For example if the pressure switch is
tripped for more than 6.05 seconds while the unit is in the
auto mode and the ram is extending, it will send a signal
to the 100% CNT counter.
Figure 42
P-EYE MENU
- The P-EYE function
will
shut down the compactor if the photo eye becomes
blocked for more than a predetermined time. The default
setting for the P-EYE function is 5 minutes
. This function prevents the unit from run-
ning indefinitely and overheating, also known as auto
shut-down.
If this timer is tripped, the Emergency Stop must be shut
OFF and switched ON to reset and resume normal oper-
ation.
Figure 43
1
2
1
2
It is important that the 100% LIT timer is set longer than the 80% LITE
timer or else the 100% light will trigger before the 80% light.
1
2