W r a p p i n g M a c h i n e M 2 3 0 - S A N D W I C H
Sec. 1 – General Information
Strada vicinale del campaccio, 1
First release
July 2017 Sec. 1 - Pag. 11
20014
– S. Ilario M.se di Nerviano
Tel: +39 0331 534.754 r.a.
– FAX: +39 0331 534.755
3. USER DUTIES
The following tasks, requirements and works are to be seen to by the user:
Set up of the installation room, including any masonry works and/or ducts required;
Set up of the supply of compressed air near the machine as specified in Section 2 (MECHANICAL
UNIT) in paragraph 1.1.2 "Technical Specifications";
Appropriate compressed air handling upstream of the feeder;
Installation of adequate power supply upstream of the machine in accordance with the regulations in
force in the country of use;
Connection of the metal structure of the machine to the earth loop of the premises (to protect the
operators from the risk of indirect electrical contact) with a copper cable having a suitable section;
Installation of a differential switch upstream of the electrical panel in order to protect against indirect
electrical contact, described in more detail in Section 4 (ELECTRICAL PANEL AND CONTROL
PANEL)
Implementation of traffic route signs (yellow lines, which identify the transit aisles of transport vehicles).
3.1.
I
NSTALLATION ENVIRONMENTAL CONDITIONS
CAUTION
Various risks due to unforeseen environmental conditions by the manufacturer.
The proper operation of the electrical equipment is intended for the following environmental conditions
Temperature
+5°C ÷ +40°C.
Relative humidity / non
condensing
5% ÷ 95%
Max Working Altitude
2000 m
Atmospheric pressure
700 ÷ 1060 hPa
Tab.2 - Environmental limits of use