IP Class 

IP 21 

Voltage 

230 V 

Load 

3A 

Device Type 

Thermostat 

Firmware Version  03.00 

Z-Wave Version 

04.21 

Z-Wave Product Id 015f.0801.5102 

Supported Command Classes 

 

Basic 

 

Sensor Multilevel 

 

Thermostat Mode 

 

Thermostat Operating State 

 

Thermostat Setpoint 

 

Thermostat Fan Mode 

 

Thermostat Fan State 

 

Association Grp Info 

 

Device Reset Locally 

 

Zwaveplus Info 

 

Configuration 

 

Manufacturer Specific 

 

Powerlevel 

 

Firmware Update Md 

 

Association 

 

Version 

Explanation of Z-Wave specific terms 

 

Controller

 — is a Z-Wave device with capabilities to manage the network. 

Controllers are typically Gateways,Remote Controls or battery operated wall 
controllers.  

 

Slave

 — is a Z-Wave device without capabilities to manage the network. Slaves can 

be sensors, actuators and even remote controls.  

 

Primary Controller

 — is the central organizer of the network. It must be a controller. 

There can be only one primary controller in a Z-Wave network.  

 

Inclusion

 — is the process of adding new Z-Wave devices into a network. 

 

Exclusion

 — is the process of removing Z-Wave devices from the network. 

 

Association

 — is a control relationship between a controlling device and a controlled 

device.  

 

Wakeup Notification

 — is a special wireless message issued by a Z-Wave device to 

announces that is able to communicate.  

 

Node Information Frame

 — is a special wireless message issued by a Z-Wave 

device to announce its capabilities and functions.  

(c) 2019 Z-Wave Europe GmbH, Antonstr. 3, 09337 Hohenstein-Ernstthal, Germany, All 
rights reserved, www.zwave.eu. The template is maintained by 

Z-Wave Europe GmbH

. The 

product content is maintained by 

Z-Wave Europe GmbH 

, Supportteam, support@zwave.eu. 

Last update of the product data: 2018-04-27 10:14:40 

 

Summary of Contents for MCOEMH8-FC

Page 1: ...MCO Home Z Wave Thermostat 2 pipe SKU MCOEMH8 FC...

Page 2: ...afety information before using it You can find further information in the device manual Step 1 Remove the steel frame from the device and secure it onto the junction box with two screws Step 2 Insert...

Page 3: ...ave enabled device for indoor temperature control It is mainly applied to a 2 pipe Fan coil system It can read room temperature and local time and automatically control fan speed based on the temperat...

Page 4: ...erminals and tighten screws The wiring diagram is shown below Step 3 Attach the wired device on A points of the steel frame as shown first and then push the whole device into junction box Step 4 Confi...

Page 5: ...inform us whether the device is in the network or not Note Follow the same steps to exclude the device from the network After inclusion turn off the device and then turn it on Now the device is ready...

Page 6: ...to enter local time setting Touch M to switch among Week Hour and Minute and then press arrow down or arrow up to set the parameters of flashing item Press M or wait for 15s to save the value and ret...

Page 7: ...button to switch among the fan speed Low Medium High Auto Then press M or wait for 15s to confirm the choice You can find further information in the device manual Parameter Setting Under the shutdown...

Page 8: ...evice the controlling device needs to maintain a list of devices that will receive controlling commands These lists are called association groups and they are always related to certain events e g butt...

Page 9: ...erence Size 2 Byte Default Value 5 Setting Description 3 1000 Base on 0 1 unit Parameter 4 Upload time interval regularly Size 2 Byte Default Value 30 Setting Description 10 65535 Base on 1s unit it s...

Page 10: ...and even remote controls Primary Controller is the central organizer of the network It must be a controller There can be only one primary controller in a Z Wave network Inclusion is the process of ad...

Reviews: