Thermostat is suggested to be installed indoor, a place with around 1.5m height above the
floor where represents the average room temperature. It should be away from direct sunlight,
any cover, or any heat source, to avoid false signal for temperature control.
CAUTION: Cut off power supply at circuit breaker or fuse before installation to avoid
fire, shock or death!
Step 1: Remove the steel frame from the device, and secure it onto the junction box
with two screws.
Step 2: Insert all wires into the right terminals and tighten screws. The wiring diagram
is shown below.
Step 3: Attach the wired device on A points of the steel frame as shown first, and then
push the whole device into junction box.
Step 4: Confirm the device is well mounted, power on and it is ready to operate.
On/Off Setting
When power on, thermostat will display
OFF
- press power button to enter working interface.
When normal working, press power button to turn off the device,
OFF
displays and all
outputs are off.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The device needs to be
added to an existing wireless network
to communicate with the devices of this network.
This process is called
Inclusion
.