Display Accuracy: 0.1°C
Working Environment: 0~55°C; less than 95% RH (Non-condensation)
Temperature Setting: 5~35°C (Adjustable)
Dimension: 86* 86*42mm
Hole Pitch: 60-65mm (86 Standard junction box)
Z-Wave Frequency: 868.42MHz (EU)
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
1.
Make sure a device is in factory reset state before including. In doubt exclude before
include.
2.
If inclusion still fails, check if both devices use the same frequency.
3.
Remove all dead devices from associations. Otherwise you will see severe delays.
4.
Never use sleeping battery devices without a central controller.
5.
Dont poll FLIRS devices.
6.
Make sure to have enough mains powered device to benefit from the meshing
Association - one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one device
controlling another device is called association. In order to control a different device, the
controlling device needs to maintain a list of devices that will receive controlling commands.
These lists are called association groups and they are always related to certain events (e.g.
button pressed, sensor triggers, ...). In case the event happens all devices stored in the
respective association group will receive the same wireless command wireless command,
typically a 'Basic Set' Command.
Association Groups:
Group Number Maximum Nodes Description
1
1
Lifeline
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however certain
configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT:
Controllers may only allow configuring signed values. In order to set values
in the range 128 ... 255 the value sent in the application shall be the desired value minus 256.
For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 =
minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.
Parameter 1: Upload temperature format automatically
Size: 1 Byte, Default Value: 2