MCO Home

Z-Wave CO2 Monitor 230V

SKU: MCOEMH9-CO2-230

 

Quickstart

This is a Measuring Sensor Device for Europe. To run this device please connect it to your mains power supply.

MCOHome CO2 Monitor is an air quality detector which is compatible with Z-Wave technology, it is mainly used to monitor CO2 concentration.

To protect yourself and others from danger and to protect the device from damage, please read the safety information before using it.

You can find further information in the device manual.

Step 1: Separate Panel and Bottom case by removing the screw at the bottom of device. Insert all wires into the right terminals and tighten
screws. The wiring diagram is shown below.

Pay attention to the current direction of positive and negative, otherwise device will easily be burn!

Step 2: Mount the Bottom case onto wall with two screws (M4*25mm).The hole pitch 60mm is for 86/60mm box, and 82mm is for American
120mm box.

Step 3: Mount the Panel back by aligning its tabs and card slot onto the Bottom case.

Step 4: Tighten the fastening screw and the device is ready for normal work.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart
section.

Z-Wave ensures a reliable communication by reconfirming every message ( two-way communication)
and every mains powered node can act as a repeater for other nodes (meshed network) in case the
receiver is not in direct wireless range of the transmitter.

This device and every other certified Z-Wave device can be used together with any other certified Z-
Wave device regardless of brand and origin 
as long as both are suited for the same frequency
range.

If a device supports secure communication it will communicate with other devices secure as long as
this device provides the same or a higher level of security. Otherwise it will automatically turn into a
lower level of security to maintain backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer to 

www.z-wave.info

.

Product Description

MCOHome CO2 Monitor is an air quality detector which compatible with Z-Wave technology, it is mainly used to monitor CO2 concentration in industrial,
agricultural, and residence environment, while monitoring the indoor temperature, humidity and VOC air quality. Device can be included into any Z-Wave
network, and is compatible with any other Z-Wave certified devices.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it  must be in factory default state. Please make sure to reset the device into factory default. You
can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is
recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.

Safety Warning for Mains Powered Devices
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to
the assembly of the product, the voltage network has to be switched off and ensured against re-switching.

Installation

Location:

Device is suggested to be installed indoor, a place with around 1.5m height above the floor where represents the average CO2 concentration. It should be
away from direct sunlight, any cover, or any heat source, to avoid false signal for temperature control.

Summary of Contents for MCOEMH9-CO2-230

Page 1: ...r the same frequency range If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security Otherwise it will automatically turn into a lower level of security to maintain backward compatibility For more information about Z Wave technology devices white papers etc please refer to www z wave info Product D...

Page 2: ...o exclusion respective inclusion mode Inclusion and Exclusion is then performed doing a special manual action right on the device Inclusion Including and Excluding of Z Wave network Activate Inclusion Exclusion mode in the gateway When device is powered on long press K2 can enter interface for inclusion or exclusion of Z Wave network If device has not been included into any Z Wave network before w...

Page 3: ...ontinuously increase the value VOC detection optional Device has built in a VOC sensor and four levels can be detected and shown on the display Excellent Good Average and Poor VOC toxic gases include carbon monoxide alcohol hydrogen methane isobutene ammonia and benzene etc You can find further information in the device manual Specification Power Supply AC 220V CO2 display range 0 2000ppm Default ...

Page 4: ... work out of the box after inclusion however certain configuration can adapt the function better to user needs or unlock further enhanced features IMPORTANT Controllers may only allow configuring signed values In order to set values in the range 128 255 the value sent in the application shall be the desired value minus 256 For example To set a parameter to 200 it may be needed to set a value of 20...

Page 5: ...twork It must be a controller There can be only one primary controller in a Z Wave network Inclusion is the process of adding new Z Wave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to a...