background image

                                             
                                                            www.mcohome.com                                          User Manual                                                           

 

                              3

 

   

 

Correspondence between key and endpoint number: 

1. First key correspond to endpoint 1. 

2. Second key correspond to endpoint 2. 

3. Third key correspond to endpoint 3. 

 

Multi endpoint command format: 

Byte 

Name 

COMMAND_CLASS_MULTI_CHANNEL 

MULTI_CHANNEL_CMD_ENCAP 

Source End Point 

Destination End Point 

COMMAND_CLASS_SWITCH_BASIC or COMMAND_CLASS_SWITCH_BINARY   

BASIC_SET/BASIC_GET or BINARY_SET/BINARY_GET 

Value ( 0xFF -- ON    0x0 -- OFF ) 

 

Multi Channel Association: 

 

AG 

identifier 

(Root)

 

Max 

Node   

Mapped 

endpoint 

group

 

Command Classes 

Trigger 

situation 

0x01 

 

(

EPs 

Max 

node 

is  

0

all 

endpoints

 

COMMAND_CLASS_BASIC, 

BASIC_REPORT 

 

Short  press  any 

key for one time 

all 

endpoints

 

COMMAND_CLASS_DEVICE_RESET

_LOCALLY, 

DEVICE_RESET_LOCALLY_NOTIFIC

ATION 

Touch any key 

20 times in 

succession 

 

all 

endpoints

 

COMMAND_CLASS_CENTRAL_SCE

NE, 

CENTRAL_SCENE_NOTIFICATION 

Short press any 

key for one time 

0x02 

EP1  

group 2

 

COMMAND_CLASS_BASIC,BASIC_S

ET 

Short press first 

button   

0x03 

EP2  

group 2

 

COMMAND_CLASS_BASIC,BASIC_S

ET 

Short press 

second button 

0x04 

EP3  

group 2

 

COMMAND_CLASS_BASIC,BASIC_S

ET 

Short press third 

button 

 

 

 

 

 

 

Reviews: