www.mcohome.com User Manual
4
Root device:
1.The gateway controls the root device to open, all end points will open
2.The gateway controls the root device to close, all end points will close
3.When End Point 1 opened, it will report opening status to root device.
4.When End Point 1 closed, it will report closing status to root device.
Association:
The device supports 4 association groups (AG):
AG
identifier
Max
Node
ID
Command Classes
Trigger situation
0x01
1
COMMAND_CLASS_BASIC, BASIC_REPORT
Short press any key for
one time
COMMAND_CLASS_DEVICE_RESET_LOCALL
Y, DEVICE_RESET_LOCALLY_NOTIFICATION
Touch any key 20 times in
succession
COMMAND_CLASS_CENTRAL_SCENE,
CENTRAL_SCENE_NOTIFICATION
Short press any key for
one time
0x02
5
COMMAND_CLASS_BASIC,BASIC_SET
Short press first button
0x03
5
COMMAND_CLASS_BASIC,BASIC_SET
Short press second button
0x04
5
COMMAND_CLASS_BASIC,BASIC_SET
Short press third button
Central Scene Activate Device
As a Central Scene Activate device, it supports “Central Scene CC”. When pressing the switch
button, it will send “Central Scene Notification” to Association Group 1 (normally associated to
gateway). This function is always being activated and cannot be disabled.
ZWAVE Supported Command:
1.Root Device
Command Class supported :
(supports S2 unauthenticated level)
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION,
COMMAND_CLASS_MULTI_CHANNEL,
COMMAND_CLASS_VERSION,
COMMAND_CLASS_MANUFACTURER_SPECIFIC,
COMMAND_CLASS_DEVICE_RESET_LOCALLY,
COMMAND_CLASS_POWERLEVEL,
COMMAND_CLASS_SWITCH_BINARY,
COMMAND_CLASS_CONFIGURATION,
COMMAND_CLASS_SCENE_ACTUATOR_CONF,
COMMAND_CLASS_SCENE_ACTIVATION,
COMMAND_CLASS_CENTRAL_SCENE,
COMMAND_CLASS_BASIC,
COMMAND_CLASS_FIRMWARE_UPDATE_MD