background image

 

2)

 

Output state:

Under normal working interface,press S2 twice to enter in the output state interface, if shows 

  means output state is ON,if shows 

  means output state is OFF,press S2 to switch to the next item or 

press S1/S3 to back to the normal working interface.

 

3)

 

Mode selection:

Under normal working interface,press S2 three times to enter into Mode Selection interface,

press  S1  or  S3  to  select  mode。Interface  shows 

  means  it  is  in  Manual  Mode,shows 

  means 

Energy Saving mode。After setting, press S2 to switch to the next item or after 5sec without any operation, it 
will back to the normal working interface.

 

4)

 

LED  Standby  brightness  setting:

Under  normal  working  interface,press  S2  four  times  to  enter  into 

LEDstandby brightness setting interface,press S1 or S3 to modify the brightness,there are 3 brightness level 
can be set(All dark:   Semi-bright:    Full bright:  )After setting, press S2 to switch to the next item or 
after 5sec without any operation, it will back to the normal working interface.

 

 

 

Mode settings 

Manual mode:The device control the room temperature by manual.

 

Room temperature≤Setting temp 1℃,Output ON; 

Room temperature≥Setting temperature - 1℃,Output OFF 

 

Energy-Saving mode:

Normal working interface display 

  and indoor temperature. Press S1/S3 can set the 

device opening time,20min for a period,set range:1-20min。 

Note:This mode will not follow the setting temperature and the difference of indoor temperature to 

turn ON/OFF the device.   

 

4. Z-Wave Operation                                                                                                                               

Include or Exclude from Z-wave network 

Under normal working interface,long press S1+S3 to enter in Z-wave Inclusion/Exclusion interface,interface shows 

the current Node ID(If shows“- - -”then means the device is not included in the network)。Short press S2,the device 
enter into learning mode,after learning mode is completed,the device shows Node ID。

(Note:According to Node 

ID display state,we can learn whether the device is included into Z-Wave network or not) 

 

●During Z-wave network learning period,long press S1+S3, it will force to quit Z-Wave learning state,then back to the 
normal working interface.   
●Under Z-wave setting interface,if the device is not entering in learning state,z-wave Node ID will not blink,press S1 
or S3 back to the normal working interface. 

 

Z-Wave commands supported: 

COMMAND_CLASS_ZWAVEPLUS_INFO,                   
COMMAND_CLASS_SENSOR_MULTILEVEL_V5,                 
COMMAND_CLASS_THERMOSTAT_SETPOINT,                   
COMMAND_CLASS_THERMOSTAT_MODE,   

 

COMMAND_CLASS_CONFIGURATION, 
COMMAND_CLASS_ASSOCIATION,   

COMMAND_CLASS_ASSOCIATION_GRP_INFO,         
COMMAND_CLASS_TRANSPORT_SERVICE_V2,     

 COMMAND_CLASS_VERSION,   

 

COMMAND_CLASS_MANUFACTURER_SPECIFIC,                         

COMMAND_CLASS_POWERLEVEL,                                                 
COMMAND_CLASS_DEVICE_RESET_LOCALLY,                                               