3
COMMAND_CLASS_SECURITY_2,
COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_BASIC,
COMMAND_CLASS_WAKE_UP,
COMMAND_CLASS_BATTERY,
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE,
5. Technical Parameters
6. Z-Wave Parameters Settings:
Add
Function
Byte Options
Default
Remark
1
Upload temperature
automatically
1
0x00 OFF
0x01 Upload the difference
value only
0x02 Timer upload mode
only
0x03 Upload the
diftimer upload
mode
0x01
2
Upload temperature
difference
2
Base on 0.1
℃
unit, 0x0005
by default, 5*0.1
℃
=0.5
℃
,
0x0003~0x03E8
0x0005
0.5
℃
3
Upload time interval
regularly
2
Base on 1s unit, it suggest to
be set above 30s
0x000A~0xFFFF
0x003c
30S
7
Heating period
setting(Energy Saving
Mode)
1
unit:min, range:10-120,
default:20, step value:1
20
8
Heating Time
1
Heating time should be less
than P07 value. (unit:min,
range:10-120, default:20,
step value:1)
3
Power
supply
AC/DC24V or
1.5V AAA battery*3
dry battery
Dimemtion
104*104*20mm
Accuracy
0.1℃
Material
Tempered
glass+PC alloy
Temperature
setting range
5-37℃
Wiring
connection
Wiring
terminals
Capacitive
1A
Display
White LED array
display
Summary of Contents for MH3900