5. Technical Parameters                                                                                                                                                                                                                 

 
 

 

 

 

 

 

 
 

6. Z-Wave Parameters Settings:                                                                                                                     

Add 

         

Function

 

Byte              Options 

Default 

Remark 

Upload temperature   
automatically 

0x00 OFF                       
0x01 Upload the difference 
value only 
0x02 Timer upload mode 
only 
0x03 Upload the 
diftimer upload 
mode 

0x01 

 

Upload temperature 
difference 

Base on 0.1

unit, 0x0005 

by default, 5*0.1

=0.5

0x0003~0x03E8 

0x0005 

0.5

 

Upload time interval 
regularly 

Base on 1s unit, it suggest to 
be set above 30s 
0x000A~0xFFFF 

0x003c 

30S 

Heating period 
setting(Energy Saving 
Mode) 

unit:min, range:10-120, 
default:20, step value:1 

20 

 

Heating Time 

Heating time should be less 
than P07 value. (unit:min, 
range:10-120, default:20, 
step value:1) 

 

 

 

 

 

 

 

Power 

supply 

AC/DC24V or 

1.5V AAA battery*3 

dry battery

 

Dimemtion 

104*104*20mm 

Accuracy 

0.1℃ 

Material 

Tempered 

glass+PC alloy

 

Temperature 

setting range 

5-37℃ 

Wiring 

connection 

Wiring 

terminals 

Capacitive 

1A 

Display 

White LED array 

display 

 

 