www.mcohome.com User Manual
MCOHome Technology Co., Ltd
3
Button & Display
Long press K2 3Sec to check the
Node ID
Long press K1 3Sec to modify the local
time
Operation
Local time setting
In normal display interface, long press K1 will enter the local time modification interface.
“Week” starts flashing, press K2 can switch among “MON-TUE-WED-THU-FRI-SAT-SUN”.
Choose one then press K1 will save the setting.
“Hour” starts flashing. Press K2, the value will cycle switchover from 00-23. Press K1 to save
the change.
“Minute” starts flashing. Press K2, the value will cycle switchover from 00-59. Then press K1
can save settings and return to normal display.
In the process of modification, long press K1 can save and return to the normal interface, long press
K2 can continuously increase the value.
VOC detection
Device has built-in a VOC sensor which can only be check locally (not able to check via
Z-Wave), and four levels can be detected and shown on the display:
Excellent, Good, Average &
Poor
. (VOC toxic gases include carbon monoxide, alcohol, hydrogen, methane, isobutene, ammonia
and benzene, etc.)
Fahrenheit/Celsius switch
Long press K1+K2 button, enter into Secret Menu interface, press K2 button to input the value,
press K1 to switch the value, and enter password 5166. Then press K1 to enter into Secret Menu.
Temperature display area will flash
“℃”.
1. Press K2button can switch between“ ”and“ ”
℃
℉
2. After setting, press K1 button to confirm and quit.