                                                            www.mcohome.com                                    User Manual

 

MCOHome Technology Co., Ltd 

4

 

 Calibration 

Long press K1+ K2 button, enter into Secret Menu interface, press K2 button to input the value, 

press K1 to switch the value, and enter password 1234. Then press K1 button enter into Secret Menu. 
“01” parameter number will be displayed, the current value flashes. 

1. Press K2 to modify the parameters. 
2. Press K1 as enter confirmation and switch to the next item to modify the value. 
3. After setting, press K1 to confirm then quit. 

 

Following is the information of each parameter: 

Item

 

Parameter

 

Range

 

Default Value

 

01 

Temperature Calibration

 

-5℃~+5℃ 

00℃ 

02 

Humidity Calibration

 

-9%RH~+9%RH 

00 

03 

CO2 

Calibration

 

-99~+99 

00 

04 

Backlight Brightness 

Settings   

00-09

00

  backlight 

normally open

) 

00 

 
Z-Wave Operation 

 

Including& Excluding of Z-Wave network 

Activate Inclusion/Exclusion mode in the gateway. When device is powered on, long press K2 

can enter interface for inclusion or exclusion of Z-Wave network.   

 

If  device  has  not  been  included  into  any  Z-Wave  network  before,  “-  -  -”will  display  on  the 
screen. 

 

Then  press  K2  once,  “---”  flashing  and  device  enters  into  learning  mode  to  get  a  node  ID.  If 
inclusion is success, a node ID will display on the screen. If not, “---” will stop flashing in 20s.   

 

If a node ID displays, it means the device is already in a Z-Wave network. To press K2 once can 
remove it from the network. “- - -” displays and press K1 once can return to normal work. 

 

 

Association Group 

Device supports 1 association group: 

 

For  “Notification”  purpose,  device  works  in  “Push”  mode  in  “Notification  Command  Class”.   
Use “Configuration “can set the threshold of CO2 Notification report. 
When detected value is more than setting value, device will send (CO2 Detected Event) report to 
the Group 1. And this report will keep sending in every 30 sec unless the detected value lower 
than setting value. 
Use “Notification Set” can set this unsolicited report; this function is default as “OFF”. 

 