www.mcohome.com User Manual
MCOHome Technology Co., Ltd
4
Calibration
Long press K1+ K2 button, enter into Secret Menu interface, press K2 button to input the value,
press K1 to switch the value, and enter password 1234. Then press K1 button enter into Secret Menu.
“01” parameter number will be displayed, the current value flashes.
1. Press K2 to modify the parameters.
2. Press K1 as enter confirmation and switch to the next item to modify the value.
3. After setting, press K1 to confirm then quit.
Following is the information of each parameter:
Item
Parameter
Range
Default Value
01
Temperature Calibration
-5℃~+5℃
00℃
02
Humidity Calibration
-9%RH~+9%RH
00
03
CO2
Calibration
-99~+99
00
04
Backlight Brightness
Settings
00-09
(
00
:
backlight
normally open
)
00
Z-Wave Operation
Including& Excluding of Z-Wave network
Activate Inclusion/Exclusion mode in the gateway. When device is powered on, long press K2
can enter interface for inclusion or exclusion of Z-Wave network.
If device has not been included into any Z-Wave network before, “- - -”will display on the
screen.
Then press K2 once, “---” flashing and device enters into learning mode to get a node ID. If
inclusion is success, a node ID will display on the screen. If not, “---” will stop flashing in 20s.
If a node ID displays, it means the device is already in a Z-Wave network. To press K2 once can
remove it from the network. “- - -” displays and press K1 once can return to normal work.
Association Group
Device supports 1 association group:
For “Notification” purpose, device works in “Push” mode in “Notification Command Class”.
Use “Configuration “can set the threshold of CO2 Notification report.
When detected value is more than setting value, device will send (CO2 Detected Event) report to
the Group 1. And this report will keep sending in every 30 sec unless the detected value lower
than setting value.
Use “Notification Set” can set this unsolicited report; this function is default as “OFF”.