www.mcohome.com User Manual
4
0x03
ALL ON/ALL OFF
1
0x00 forbid ALL ON, forbid ALL OFF
0x01 forbid ALL ON, allow ALL OFF
0x02 allow ALL ON, forbid ALL OFF
0xFF allow ALL ON, allow ALL OFF
0xFF
0x04
LED Backlit
brightness level
1
0x00 LED disabled
0x01~0x0A Min level-Max level
>0x0A same level as 0x0A
0x0A
0x05
Key Mode
1
0x00 single click to switch on/off status
0x01 Key default as off state. When it is
turned on, then it will be turned off
automatically after a time period , which
can be set in item 0x06
0x02 Key default as on state. When it is
turned off, then it will be turned on
automatically after a time period , which
can be set in item 0x06
0x03 hold >3s then key is on, and off once
released
0X04 single click to switch on/off
hold >3s then key is on, and off once
released
0x00
This function
works for
corridor or
stairwell
situation.
0x06
Key On duration
2
0x00 infinite
1~65535 unit "sec"
0x00
0x08
Basic CC integration
setting
1
0x00 "Basic Set" received
,
key 1 responds;
"Basic Get" received
,
key 1 sends "Basic
Report"; key 1 will not send unsolicited
"Basic Report"
(
No Endpoint
)
to LifeLine
Association
0x01 "Basic Set" received
,
key 1 responds;
"Basic Get" received
,
key 1 sends "Basic
Report"; key 1 will send unsolicited "Basic
Report"
(
No Endpoint
)
to LifeLine
Association
0x02 "Basic Set" received
,
all keys
respond; "Basic Get" received
,
not reply
"Basic Report"; All keys will not send
unsolicited "Basic Report"
(
No Endpoint
)
to LifeLine Association
0x03 "Basic Set" received
,
all keys
respond; "Basic Get" received
,
key 1
sends "Basic Report"; All keys will not
send unsolicited "Basic Report"
(
No
Endpoint
)
to LifeLine Association
0x00
This parameter
works for
integration with
different
gateways/syste
ms. If do not
know how to
use, pls keep as
default.