Electrical Heating Thermostat 

MH4-US 

 

                                                              Introduction                                                     

 

MH4-US is a Z-Wave enabled device for indoor temperature control. It is mainly applied to 

control electrical heating  systems, such as heating  film, heating cable, heater, etc.  With the floor 

over-heating  protection and GFCI (Ground Fault Circuit Interrupter) function, this  device works 

as  a  reliable  indoor  temperature  controller.  Besides  its  stable  performance,  the  unique  design  is 

also  an  attractive  feature  for  end  users.  Moreover,  a  built-in  Z-Wave  module  makes  it  a  smart 

device which can be operated in any Z-Wave network with other Z-Wave certified devices . 

 

Features

 

 

Tempered glass panel with capacitive touch buttons   

 

With two sensors to detect indoor& floor temperature 

 

Floor overheating protection 

 

GFCI(leakage protection): level 5mA 

 

Multi-working modes to meet various user needs:   

 

Time Period(Schedule) Mode               

 

Comfort Mode                                                 

 

Energy-saving Mode                   

 

Vacation Mode 

 

Programmable schedule: 4 periods each day of 7 days; 5+2; 5+1+1

 

                                                              Specification                                                       

 

Power supply: AC120V/AC240V, 60Hz 

 

Max output: 1800W at 120AC ; 3600W at 240AC 

 

Self-consumption: <2W 

 

Temp. format: 

 

/

 ; Time format: 12h / 24h   

 

Z-Wave frequency: 908.42MHz   

 

Panel dimension: 76*120*20mm 

 

Vertical installation

hole pitch 82mm 

American 120 box 

 

 

                                                               

  Safety Information   

                                                   

To protect yourself and others from danger and to protect the device from damage, please read the 

safety information before using it. 

Important! 

 

 

A qualified electrician with the understanding of wiring diagrams and knowledge of electrical 

safety should complete installation following the instructions. 

 

Before installation, please confirm the real voltage complying with the device’s specification. 

Cut off any power supply to secure the safety of people and device.   

Summary of Contents for MH4-US

Page 1: ... Floor overheating protection GFCI leakage protection level 5mA Multi working modes to meet various user needs Time Period Schedule Mode Comfort Mode Energy saving Mode Vacation Mode Programmable schedule 4 periods each day of 7 days 5 2 5 1 1 Specification Power supply AC120V AC240V 60Hz Max output 1800W at 120AC 3600W at 240AC Self consumption 2W Temp format Time format 12h 24h Z Wave frequency ...

Page 2: ...h around 41 2 to 5 feet height above the floor where represents the average room temperature It should be away from direct sunlight any cover or any heat source to avoid false signal for temperature control CAUTION Cut off power supply at circuit breaker or fuse before installation to avoid fire shock or death Step 1 Separate the device with a flat head screwdriver into two parts the display panel...

Page 3: ...creen and all outputs will be closed GFCI Test Enter into GFCI test In the normal working interface when the electrical heating is working press GFCI button the icon of GFCI will be displayed on the screen and the output of electrical heating is closed indicator light is on Exit from GFCI test slide the ON OFF button to turn it off and then turn it on the device will back to the normal working int...

Page 4: ...ting of WEEK press button to switch to HOUR HOUR is blinking press or button to set the values When finish the setting of HOUR press button to switch to MINUTE MINUTE is blinking press or button to set the values When finish the setting of MINUTE press button or delay for 10s without any operation to save all the values and return to the normal working interface automatically During setting press ...

Page 5: ...orking interface press and buttons simultaneously the displayed temperature will be switched between the room temp and floor temp Keypad Lock In the normal working interface press and buttons simultaneously to lock the keypad at the same time the icon will be displayed on the screen When the keypad is locked you cannot do any operation of it When the icon of Keypad Lock displays on the screen pres...

Page 6: ... turned off the icon disappeared Room Temperature Control Mode When the icon displays on the screen indicates the system is in Room Temperature Control Mode when the icon displays on the screen it indicates the current temperature that displayed on the screen is the indoor temperature When the detected indoor temperature the set temperature for 2 5 electrical heating will be turned on and the icon...

Page 7: ...erature the set temperature electrical heating will be turned off and the icon will be disappeared meanwhile the Relout close turn off output signal The setting default temperature is 16 5 61 on the remote control mode Notes Remote signal control output has the highest priority Sensor Failure When sensor failed to work the icon EEE will display on the screen The output will be closed Cumulative Ti...

Page 8: ...ges or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment FCC Interference Statement Part 15 105 b USA only This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful i...

Page 9: ... INSTALLATION ACCIDENT ABUSE MISUSE NATURAL DISASTER INSUFFICIENT OR EXCESSIVE ELECTRICAL SUPPLY ABNORMAL MECHANICAL OR ENVIRONMENTAL CONDITIONS OR ANY UNAUTHORIZED DISASSEMBLY REPAIR OR MODIFICATION This limited warranty shall not apply if i the product was not used in accordance with any accompanying instructions or ii the product was not used for its intended function This limited warranty also...