(8) EXT frequency switch: Press this switch, LED window will display EXT signal frequency 

or counter value. 

(9)  Level  adjustment:  Press  level  adjustment  switch,  the  light  “level”  is  on,  then  adjusting 

level adjustment rotary can change DC level offset. 

(10) Amplitude: The voltage output amplitude will be big while turning it clockwise, and the 

value will be small while turning it counterclockwise. 

(11) Voltage out: voltage is out via this terminal. 

(12) TTL out: TTL is out via this terminal. 

(13) VCF: Voltage controlling frequency change input is via this terminal. 

(14) SYMMETRY: sym switch, duty adjustable rotary, press duty switch, the light “SYM” is 

on; adjusting duty rotary can change the duty of wave. 

3. BASIC OPERATION METHODS: 

Before power is on, fist check the input voltage, insert the power line into the AC socket in 

the rear panel. Set each controlling knob as the following table: 

POWER Knob 

Spring out 

ATTE Knob 

Spring out 

COUNTER Knob 

Spring out 

LEVEL Knob 

Spring out 

DUTY Knob 

Spring out 

After  that, turn  on  the  switch.  The  function  signal  generator  acquiesce  10k  sine  wave,  LED 

window display it’s out signal frequency. 

5.1 Deliver the voltage out signal to oscilloscope Y input terminal via amplitude terminal. 

5.2 Triangle

square

sine wave form:

   

5.2.1 Press sine

square

triangle wave, the screen of oscilloscope will display sine

square

and triangle. 

5.2.2  Press  frequency  range  selector  and  rotate  the  frequency  rotation,  the  waveform  on  the  oscilloscope’s  screen  and 

frequency on LED window will change evidently. 

5.2.3 Turn the amplitude rotary to maximum, the wave amplitude on the oscilloscope’s screen will be 

20Vp-p 

5.2.4 Press “LEVEL”, turn the “level” rotary to max, wave on oscilloscope will move upside, and vise visa. The max change 

should be ±10V or more. NOTICE: when signal is over ±10V or ±5V (50

Ω

),the amplitude is limited. 

5.2.5 Press “ATTE”, the out waveform will be attenuated. 

4. INSTRUMENT ACCESSORIES: 

The standard accessories are as following: 

(1) Function Signal Generator                                                                    1 set 

(2) Connect cable                                                                                        1 piece 

(3) Operation manual                                                                                  1copy 

(4) Fuse                                                                                                        1piece 

(5) Power cord                                                                                            1piece                                                             