background image

 

MCZ CONTROL - MODEM GSM 

 

 

Modem GSM ACTIVE SYSTEM 

MCZ GROUP S.p.A. all rights reserved 

 

INTRODUCTION 

Specifications can be altered without any pre-warning. 
Some  terms  used  in  this  document  can  be  other 
companies' factory brands and are mentioned as 

examples without violating the legitimate rights of the 

owners. 
Even though the content of this manual has been 

accurately controlled, MCZ cannot be held responsible 

for any damage or loss derived from information 
contained in the present document.  
 

GUARANTEE 

MCZ guarantees its products for two years from the 

date of manufacturing and reserves the right to repair 
and/or replace the products or components that are 

faulty due to the material used and/or manufacturing 

process or that are non-compliant with the 

specifications or order. No further explicit or implicit 

guarantee nor any cover for loss revenue is provided. 

In no cases can MCZ be held responsible for any 
consequences or damage resulting from the use 

of its products. 

 

MAINTENANCE 

Handle the SIM card with care. Do not bend or scratch 

the SIM card and avoid exposing it to static electricity. 
Do not use any chemical substances to clean the SIM 

card or MczControl.  
Do not remove any cover or markings from MczControl. 
 

SAFETY WARNINGS 

Do not install MCZControl close to medical equipment 
like pacemakers or hearing aids. MCZControl can 

interfere with the operations of this equipment.  
Do not install MczControl close to petrol stations, fuel 

depots, chemical plants or explosion sites where 

MCZControl can disrupt the operation of technical 

devices. 
MczControl can generate interference if deployed close 

to televisions, radios or personal computers. 
In order to avoid potential damage it is recommended 

the use of tested and specified accessories like those 

compatible with MczControl. No accessories are 
covered by the warranty. 
MczControl is subject to a complete functional test. The 

specifications are based on the characteristics of the 

tested sample units and do not refer to measurements 

carried out on each single unit. 
The warranty does not cover improper use of the 
equipment. 
 
 
 
 

PRODUCT DESCRIPTION 

MczControl is a civil GSM terminal for the supervision 

and control of MCZ stoves through the use of advances 
functions available through the GSM network. 
The interfaces, connections and integrated SIM card 

decoder make this rapid use and simple GSM terminal 

in a domestic environment.  

 
TECHNICAL CHARACTERISTICS 

 

Dual-band EGSM 900/1800 MHz 

 

Sensitivity better than -106dBm 

 

Output power: 

o

 

Class 4 (2W) for 900 MHz 

o

 

Class 1 (1W) for 1800 MHz 

 

Integrated antenna 

 

Powered by an internal 340mAh Li-Ion battery  

 

External power for battery charging: 9÷24 Vdc, 

6÷21 Vac 

 

Average consumption of battery during 

charging: 70mA 

 

1200 baud optoisolated asynchronous serial 

communication port 

 

No. 2 status indicator leds, no. 1 reset button 

 

ABS container (UL 94 HB) 

 

Level of protection EN-60529: IP30 

 

Dimensions: L=102mm, W=54mm, H=30mm 

 

Indicative weight: 180 g 

 

Operating temperature: -10 ÷ +55°C 

 
INSTALLATION 

MczControl must be installed by qualified personnel. 
MczControl can be used only on specific models of MCZ 

stoves and specifically only on those equipped with 

ACTIVE SYSTEM technology 
MczControl uses an internal rechargable Li-Ion battery: 
please adhere to the specific guidelines. 
The cable connecting MczControl to the stove must be 

that provided by MCZ: in cases where the supplied 

cable is not of the correct length, purchase a cable of 

greater length from the catalogue. In the connecting 

cable the voltages and the signals are at Safety 
Extremely Low Voltage (SELV) 
MczControl must be installed using the appropriate 

bracket provided at the rear of the stove. In cases 

where the location does not allow a good GSM 

connection wall-mount it using, where necessary, a 

cable of greater length (non-standard accessory).  
Electrical safety in the case of a fault is guaranteed by 

an internal fuse and appropriate mechanisms provide 

protection against external power surges. 

 
 
 
 
 

Summary of Contents for MczControl

Page 1: ...I D F MANUALE DI USO ED INSTALLAZIONE AUFBAU UND BEDIENUNGSANLEITUNG NOTICE D INSTALLATION ET D EMPLOI INSTALLATION AND USE MANUAL...

Page 2: ...copre alcuno di questi accessori MczControl sottoposto ad un collaudo funzionale completo Le specifiche sono basate sulla caratterizzazione delle unit campione testate non si riferiscono a misure effe...

Page 3: ...deve essere inserita nell alloggiamento per attivare il funzionamento di MczControl La SIM card da inserire deve essere preventivamente configurata per il servizio SMS ad es inserendola in un telefono...

Page 4: ...SMS Short Message Service con il vostro telefono cellulare GSM Per poter utilizzare tale dispositivo necessario acquistare da un operatore telefonico qualsiasi una SIM Card eccetto per l operatore 3...

Page 5: ...parete pi vicina all apparecchio la staffa di ancoraggio del modem utilizzando le due viti in dotazione se si decide di avvitare la staffa alla stufa oppure due viti con tasselli tipo Fischer se si d...

Page 6: ...zzando le due viti in dotazione se si decide di avvitare la staffa alla stufa oppure due viti con tasselli tipo Fischer se si decide di fissare la staffa al muro Il cavo di collegamento munito di dopp...

Page 7: ...ulo spento Spento Ricerca rete GSM Non registrato in spegnimento Lampeggiante veloce Ton Toff 0 5 sec Registrato alla rete GSM e in stand by Lampeggiante lento Ton 0 3 sec Toff 2 7 sec Chiamata di con...

Page 8: ...ltro Quando lo stato della stufa corrisponde al comando ricevuto viene inviato un messaggio SMS di conferma dell avvenuto comando Se la stufa si trova in stato di allarme bloccante l sms di risposta i...

Page 9: ...ceve un comando di ON dal modem e si accende anche se il telecomando rimane spento 4 6 Informazioni generali sul funzionamento Verificare che la SIM sia inserita nel modem prima di collegarlo alla stu...

Page 10: ...ab MczControl wird einem vollst ndigen Betriebsendtest unterzogen Die Spezifikationen basieren auf der Charakterisierung der getesteten Stichprobeneinheiten Sie beziehen sich nicht auf Messungen die...

Page 11: ...r von mindestens 32 kB Die SIM Karte muss in den Sitz eingef hrt werden um den Betrieb von MczControl zu aktivieren Die einzusetzende SIM Karte muss zuvor f r das SMS Service konfiguriert werden z B i...

Page 12: ...chricht Short Message Service mit Ihren GSM Mobiltelefon Um dieses Ger t zu benutzen muss man von irgendeinem beliebigen Telefonanbieter mit Ausnahme des Anbieters 3 der nicht kompatibel ist eine SIM...

Page 13: ...fens oder an der dem Ger t am n chsten liegenden Wand befestigen Dazu die zwei mitgelieferten Schrauben befestigen wenn man den B gel am Heizofen befestigen m chte oder die zwei Schrauben mit Fischerd...

Page 14: ...zwei mitgelieferten Schrauben befestigen wenn man den B gel am Heizofen befestigen m chte oder die zwei Schrauben mit Fischerd beln benutzen wenn man den B gel an der Wand befestigen m chte Das Anschl...

Page 15: ...Leuchtet fest Die Led LINK zeigt die folgenden Betriebszust nde von MczControl Betriebsstatus Led LINK gelb Modul ausgeschalten Aus Suche GSM Netz Nicht registriert schaltet sich aus Schnelles Blinke...

Page 16: ...lton als Empfangsbest tigung an den gespeicherten Sender gesendet Nach 15 s werden maximal 3 Versuche einer Statusabfrage an den Heizofen gesendet in Abst nden von 3 Sekunden voneinander Wenn der Heiz...

Page 17: ...Befehl vom Modem erh lt schaltet er sich aus auch wenn die Fernbedienung weiter eingeschalten bleibt Genauso wenn der Heizofen ausgeschalten ist er erh lt einen ON Befehl vom Modem und schaltet sich e...

Page 18: ...compatibles avec MczControl La garantie ne couvre pas lesdits accessoires MczControl est soumis une s rie compl te de tests et d essais de fonctionnement Les sp cifications sont bas es sur la caract...

Page 19: ...d au moins 32 Ko La carte SIM doit tre ins r e dans son logement pour pouvoir activer le fonctionnement de MczControl Avant d ins rer la carte il faut d abord la configurer pour le service SMS par ex...

Page 20: ...artir de votre t l phone mobile GSM Pour utiliser ce dispositif il est n cessaire d acheter une carte SIM aupr s d un gestionnaire de t l phone except es les carte de l op rateur 3 qui ne sont pas com...

Page 21: ...du modem au dos du po le ou sur un mur voisin l appareil Utiliser les deux vis fournies en dotation pour visser l trier au po le ou utiliser deux vis et chevilles de type Fischer en cas de fixation au...

Page 22: ...les deux vis fournies en dotation pour visser l trier au po le ou utiliser deux vis et chevilles de type Fischer en cas de fixation au mur Le c ble de connexion est dot d un connecteur t l phonique ch...

Page 23: ...u GSM Non enregistr en extinction Clignotement rapide Ton Toff 0 5 sec Enregistr sur le r seau GSM et en stand by Clignotement lent Ton 0 3 sec Toff 2 7 sec Appel de confirmation en cours Allum en mod...

Page 24: ...la commande re ue un message SMS de confirmation de commande ex cut e est envoy Si le po le est en tat de blocage cause d une alarme le SMS de r ponse informe du d clenchement d alarme et en indique l...

Page 25: ...e OFF de la part du modem il s teint m me si la t l commande continue rester allum e De m me lorsque le po le est teint et re oit une commande de ON de la part du modem il s allume m me si la t l comm...

Page 26: ...ctional test The specifications are based on the characteristics of the tested sample units and do not refer to measurements carried out on each single unit The warranty does not cover improper use of...

Page 27: ...e SIM card must be inserted in the housing in order to activate the operation of MCZControl The SIM card to be used must be preconfigured for SMS for example by inserting it in a mobile phone and usin...

Page 28: ...r of your equipment through an SMS from your GSM mobile phone In order to be able to use this device purchase a SIM Card from any operator except from 3 which is not compatible The SIM Card clearly ha...

Page 29: ...modem supporting bracket on the back of the stove or on the nearest wall to the device using the provided screws if the bracket is installed on the stove or two expansion Fischer type screws if the b...

Page 30: ...ice using the provided screws if the bracket is installed on the stove or two expansion Fischer type screws if the bracket is wall mounted The connecting cable is equipped with twisted pairs on both e...

Page 31: ...egistered on the GSM network and in stand by Slow flashing Ton 0 3 sec Toff 2 7 sec Confirmation call in progress On steady 4 2 CONTROL BUTTONS On the front panel a slot to access the internal reset b...

Page 32: ...rm of the presence and type of alarm If the stove does not receive the command for example due to network problems the reply SMS is not sent and the command is to be considered NOT executed The SMS re...

Page 33: ...emains switched on The same applies when the stove is off and receives an ON command from the modem in which case it switches on even though the remote control remains switched off 4 6 General informa...

Page 34: ...MCZ GROUP S p A Via La Croce n 2 33074 Vigonovo di Fontanafredda PN ITALY Telefono 0434 599599 r a Fax 0434 599598 Internet www mcz it e mail mcz mcz it 8901000700 Rev 0 03 2010...

Reviews: