MCZ CONTROL - MODEM GSM
8
Modem GSM ACTIVE SYSTEM
MCZ GROUP S.p.A. all rights reserved
4.4. OPERATING FUNCTIONS
Send an SMS to the number of the SIM inserted in MCZControl through your mobile phone. The message must
have a precise syntax which will be indicated below
(the modem is not Caps sensitive):
4.4.1 SMS MESSAGE COMMANDS
INSTRUCTION
SMS
Switching on at medium power (3) and medium
ventilation (3)
ON
Switching on/power adjustment 1, 2, 3, 4 or 5 and
AUTOMATIC ventilation i.e. equal to the power of the
flame.
ON1 – ON2 – ON3 – ON4 – ON5
without spaces, e.g.:
ON4 (valid)
ON 4 (not valid)
Switching off of the device
OFF
Quering of the device operating status
TESTING
The procedure is composed of the following phases:
•
If the received command is deemed valid the number of the sender is saved and updated and the serial
command to switch on/off or adjust is sent to the stove.
•
A received notification is sent to the number of the sender.
•
After 15 seconds a maximum of 3 status requests are sent to the stove, at 3 second intervals. When the
status of the stove corresponds to the received command, an SMS is sent confirming the execution of the
command. If the stove is in an alarm blocking status, the return SMS will inform of the presence and type
of alarm.
•
If the stove does not receive the command (for example due to network problems), the reply SMS is not
sent and the command is to be considered
NOT
executed.
•
The SMS received by the SIM card of MCZControl is deleted immediately after execution and the modem
returns to "a ready to receive SMS" status.
Between a command request (SMS) and the next, wait at least three minutes to allow the
modem to carry out the entire procedure set out by the communication protocol.
4.4.2. PRACTICAL EXAMPLES OF COMMAND AND REPLY
SMS
command
Command meaning
Stove reply SMS
Reply meaning
ON
Switching on/setting of stove with
power set to 3 and ventilation in
AUTO
ON3 – OK
Stove on/set as requested
ON5
Switching on/setting of stove with
power set to 4 and ventilation in
AUTO
ON5 – OK
Stove on/set as requested
ON
Switching on/setting of stove with
power set to 3 and ventilation in
AUTO
ALARM A02
An alarm is impeding the
stove to switch on
OFF
Extinguishing the stove
OFF – OK
Stove off as requested
TESTING
Stove status request
ON5 – OK
Stove on with power set to 5
TESTING
Stove status request
OFF – OK
Stove off
TESTING
Stove status request
ALARM A01
Stove with failed to switch on
alarm (for example)
If the switch of the small emergency panel is set to OFF the stove will ignore commands
from the modem and hence the user will not receive an SMS confirming the execution of