CSP
−
902RFM207E
−
1
ROTORCRAFT FLIGHT MANUAL
MD900 (902 Configuration with PW 207E)
Emergency and
Malfunction Procedures
FAA Approved
Reissue 2
Revision 2
3
−
42
IIDS
Indications:
Yellow IIDS annunciator ON.
Conditions:
IIDS fault
Procedures:
Continue flight.
Check fault log after landing; advise maintenance.
3
−
15. OTHER MALFUNCTION/ADVISORIES
IIDS FAILURE
Indications:
IIDS displays blanks.
Conditions:
Loss of electrical power to IIDS.
Procedures:
On ground
Shut down.
Procedures:
In flight
Reduce airspeed to 100 KIAS or less.
Reduce electrical load.
Land as soon as practical.
BATTERY DISCHARGE
Indications:
BATT DISCHARGE message on IIDS alphanumeric display.
Conditions:
Battery bus voltage less than 26 volts.
Procedures:
Do not clear the BATT DISCHARGE message.
NOTE
:
The IIDS will display the BATT DISCHARGE message whenever the Battery Bus
Voltage is <26V for >5 seconds, or <22V for >0.5 seconds. Clearing the BATT
DISCHARGE message by pressing CLR will result in no further indication of the
electrical system health unless the condition which set the message corrects
itself AND a low voltage condition occurs again.
Check generator load indications.
Land as soon as practical if condition persists.
Advise maintenance.
Summary of Contents for MD900 Explorer