CSP
−
902RFM207E
−
1
ROTORCRAFT FLIGHT MANUAL
MD900 (902 Configuration with PW 207E)
Emergency and
Malfunction Procedures
FAA Approved
Reissue 2
Original
3
−
44
GROUND POWER UNIT DOOR OPEN
NOTE
:
Helicopters with aft mounted batteries only.
Indications:
Yellow
GPU
indicator light ON.
Conditions:
External power door open.
Procedures:
On ground.
Close door. If light remains ON with door closed, advise maintenance after
completion of flight.
In the air: advise maintenance after completion of flight.
Procedures:
In the air
Advise maintenance after completion of flight.
3
−
16. VIBRATIONS
Indications:
Sudden, unusual or excessive vibrations occurring during flight.
Conditions:
The onset of unusual or excessive vibrations in the helicopter may be an
indication of problems in the rotor or drive train systems.
Procedures:
LAND AS SOON AS POSSIBLE.
No further flights should be attempted until the cause of the vibration
has been identified and corrected.
Indications:
“CHECK NOTAR BAL” or “CHECK ROTOR BAL”
on IIDS
alphaneumeric
display.
Conditions:
NOTAR fan or main rotor balance out of acceptable range.
Procedures:
Clear message from adphaneumeric display.
Land as soon as practical.
If the message on alphaneumeric display reappears during the
same flight, land as soon as possible.
Advise maintenance.