CSP
−
902RFM207E
−
1
ROTORCRAFT FLIGHT MANUAL
MD900 (902 Configuration with PW 207E)
Systems Description
Original
7
−
38
Reissue 2
The key switch
is located on the right hand side of the instrument panel. All
switches and brightness controls that operate the electric system are on the console.
The ground power receptacle
for 28 volts DC is in the right hand side of the
fuselage below and forward of the pilot's door.
Two grounding jacks
are located on the right hand side of the fuselage, one ad
jacent to the ground power receptacle (forward mounted batery) and one adjacent
to the fuel filler port.
Circuit breakers
for essential circuits are located in the cockpit on the Left and
Right Essential Bus panels; nonessential breakers are located in the baggage
compartment ceiling. One 29 volt DC outlet is located in the cockpit on the copilot's
side of the console, and another one is on the left hand cabin wall aft of the cabin
door.
Aircraft Lighting:
Aircraft Interior Lighting:
Cockpit:
Floodlight
(1)
Map Light
(1)
Instrument Floodlights
(3) (Powered By Right Essential Bus)
Main Cabin:
Threshold Lights
(2)
Baggage Compartment:
Floodlight
(1)
Aircraft Exterior Lighting:
Nose:
Fixed Landing Light
(1)
Fixed Hover Light
(1)
Empennage:
Left End of Horizontal Stabilizer:
Red Navigation Light
(1)
Right End of Horizontal Stabilizer:
Green Navigation Light (1)
Top Center of Stabilizer:
Flashing Red Anticollision Light (1)
White Navigation Light (1)
Bottom of Tailboom, Forward of Thruster:
Flashing Red Anticollision Light (1)
White Navigation Light (1)