CSP
−
902RFM207E
−
1
ROTORCRAFT FLIGHT MANUAL
MD900 (902 Configuration with PW 207E)
Systems Description
Original
7
−
66
Reissue 2
BALANCE MONITOR
MAIN ROTOR
BALANCE
NOTE: TO RETURN TO PREVIOUS HIGHER LEVEL - PRESS
MENU
CLEAR FAULT
LOG
CLEAR ADVISORY
LOG
CLEAR SPECTRUM
LOG
NOTAR
BALANCE
SPECTRUM
MAIN ROTOR TRACK
FORMAT DATABASE
AND RESET BMS
CLEAR M/R
BALANCE LOG
CLEAR NOTAR
BALANCE LOG
CLEAR ALL LOGS
CLEAR SETUP
CONFIGURATION
BMS ADVISORY LOG
BMS FAULT LOG
BMS VERSION LOG
BMS MAINTENANCE
TOP LEVEL
SECOND LEVEL
THIRD LEVEL
NOTE 1: FOR ALL ``CLEAR'' MENU SELECTIONS, PRESS ENT KEY AND A ``PRESS TO
CLEAR'' MESSAGE WILL BE DISPLAYED. PRESS REC KEY TO CLEAR THE LOG
AND A ``CLEARED OK PRESS ANY KEY'' MESSAGE WILL BE DISPLAYED.
PRESSING ANY KEY WILL RETURN TO THE ``CLEAR LOG MENU''.
NOTE 2: PRESS ENT KEY AND A ``PRESS TO FORMAT AND RESET'' MESSAGE WILL
BE DISPLAYED. PRESS REC KEY TO FORMAT THE DATA BASE AND A ``DBASE
FORMATTED INITIALIZING BMS'' MESSAGE WILL BE DISPLAYED. PRESSING
ANY KEY WILL RETURN TO THE ``CLEAR LOG'' MENU AFTER 30 SECONDS
NOTE 1
NOTE 2
f92
−
095
Figure 7
−
40. Balance Monitor, BMS Maintenance
Summary of Contents for MD900 Explorer