Optional Equipment
Smoke Detector
CSP
−
902RFM207E
−
1
ROTORCRAFT FLIGHT MANUAL
MD900 (902 Configuration with PW 207E)
Original
10
−
90
FAA Approved
Reissue 2
After landing:
Engine control switches
OFF
Rotor brake (if installed)
APPLY
Power switch
OFF
Passengers/crew
EVACUATE
PART IV
NORMAL PROCEDURES
PRE FLIGHT CHECKS: ELECTRICAL POWER ON
Baggage compartment:
Circuit breaker panel cover
REMOVE
SMOKE DET press-to-test button
PRESS
Listen for smoke detector warning tone in
headset.
CHECK
NOTE
:
A second crew member is required to perform this check.
Circuit breaker panel cover
REPLACE
RH REAR FUSELAGE
SHELL ASSEMBLY
SMOKE
DETECTOR
f927
−
118
RIGHT AVIONICS BUS
HDG
SAS/AP
ADF
26 VAC BUS
ADF1
FM
CTRL
FM1
RT
FM2
RT
FM3
RT
DME
STORM
SCOPE
CAMERA
NAV 1
RMI
PRESS TO
TEST
SMOKE
DET
BAGGAGE COMPARTMENT
CIRCUIT BREAKER PANEL
Figure 10
−
33. Smoke Detector and Press
−
To
−
Test Switch Location.
Summary of Contents for MD900 Explorer