CSP
−
902RFM207E
−
1
ROTORCRAFT FLIGHT MANUAL
MD900 (902 Configuration with PW 207E)
Emergency and
Malfunction Procedures
FAA Approved
Reissue 2
Original
3
−
16
ELECTRICAL FIRE
Indications:
Smoke and fume accumulation in the cabin.
Conditions:
On ground
Procedures:
Engine control switches
OFF
Passengers/crew
EVACUATE
Rotor brake (if installed)
APPLY
Power switch
OFF
Conditions:
In flight
Procedures:
Cabin heat
OFF
Fresh air vents
OPEN
Generator switches
OFF
If smoke/fire conditions persist:
POWER switch
ESNTL
Land as soon as possible.
After landing:
Engine control switches
OFF
Rotor brake (if installed)
APPLY
Power switch
OFF
Passengers/crew
EVACUATE