CSP
−
902RFM207E
−
1
ROTORCRAFT FLIGHT MANUAL
MD900 (902 Configuration with PW 207E)
Emergency and
Malfunction Procedures
FAA Approved
Reissue 2
Original
3
−
30
GENERATOR HIGH LOAD
Indications:
Upper yellow generator high load annunciator ON.
Procedures:
Turn off unnecessary electrical equipment.
Failure to turn off unnecessary electrical equipment may cause
the generator(s) to automatically go off line.
GENERATOR
Indications:
Yellow GEN annunciator ON and %LOAD is ``0''.
Procedures:
L GEN or R GEN (or both if dual generator
failure) switch
RESET
If GEN annunciator still ON
OFF FOR AFFECTED
GENERATOR(S)
Continue flight.
If both generators failed.
Power switch
ESNTL UNLESS FLIGHT
CONDITIONS DICTATE
OTHERWISE
NOTE
:
With both generators failed and the power switch in the ESNTL position, a fully
charged battery will supply power for at least 30 minutes.
WIth the power switch in the ESNTL position, only that equipment powered by
the essential bus will be operational.
Land as soon as practical.