CSP
−
902RFM207E
−
1
Emergency and
Malfunction Procedures
ROTORCRAFT FLIGHT MANUAL
MD900 (902 Configuration with PW 207E)
FAA Approved
Reissue 2
Original
3
−
37
FUEL SHUTOFF VALVE MALFUNCTION
Indications:
Two yellow bar segments flashing above and below the fuel flow line
to the left or right of center.
Conditions:
Fuel valve not fully opened/closed
Procedures:
In flight:
Continue flight
Be prepared for affected engine to flame out
Pre Start:
Fuel shutoff switch
CYCLE OFF TO ON
If no change in indication
DO NOT ATTEMPT START