CSP
−
902RFM207E
−
1
ROTORCRAFT FLIGHT MANUAL
MD900 (902 Configuration with PW 207E)
Normal Procedures
FAA Approved
Reissue 2
Original
4
−
28
4
−
12. ENGINE/AIRCRAFT SHUTDOWN
−
NORMAL
NOTE
:
Shut down the engines before exiting the helicopter unless safety or operational
considerations dictate otherwise.
Maximum demonstrated wind speed for starting and stopping the rotor is 50
knots.
Collective stick
FULL DOWN; FRICTION ON
Cyclic stick
TRIM TO NEUTRAL
Pedals
NEUTRAL
Engine control panel
L ENGINE and R ENGINE
SET TO IDLE
All unnecessary electrical equipment
OFF
Utility panel:
Heat
OFF
AC (if installed)
OFF
Pitot heat (if installed)
OFF
IPS (if installed)
OFF
Lighting control panel
AS DESIRED
Electrical master panel:
Avionics master switch
OFF
L GEN/R GEN switches
OFF
Fuel system panel:
L BOOST/R BOOST
OFF
Failure to turn OFF boost pumps will result in engine fuel nozzle
coking over time.
CAUTION
Summary of Contents for MD900 Explorer