www.marketdirect.com.au
Ph: 1300 494 494
60
Times of flashes
of LED
Troubleshooting
1
Check whether the fuel pipe is blocked or whether the fuel in the
tank is sufficient.
a. Check whether the exhaust pipe is blocked.
b. Check whether fuel mass is appropriate.
2
a. Check whether the fuel pipe is blocked or whether the fuel in the
tank is sufficient.
b. Check whether the exhaust pipe is blocked.
c. Check whether fuel mass is appropriate.
d. Replace the fuel pump
3
Abnormal voltage, if the voltage is very low, then battery should be charged.
4
a. Use ventilation mode cooling if temperature over high.
b. Or replace controller.
6
Replace controller
7
a. Check whether fuel pump lead connection is reliable.
b. Replace fuel pump.
c. Replace controller.
8
a. Check whether the fan wheel have any scrape.
b. Replace fan motor assembly.
c. Replace controller.
9
a. Clean the carbon deposition of glow plug.
b. Replace glow plug.
c. Replace controller.
10
a. Whether air inlet and outlet are blocked.
b. Whether junction box cover tightly.
c. Whether inlet air and exhaust air short circuit.
11
a. Check overheat sensor (normal temperature resistance is about 1kΩ).
b. Replace overheat sensor.
12
a. Check connection of control switch.
b. Replace control switch.
13
Need to clean up the carbon deposition and maintenance work.
14
Replace controller.
Summary of Contents for FORBES 13 2021
Page 25: ...www marketdirect com au Ph 1300 494 494 21 Electrical Diagrams Switch Panel...
Page 26: ...www marketdirect com au Ph 1300 494 494 22 Main Circuit...
Page 43: ...www marketdirect com au Ph 1300 494 494 39...
Page 48: ...www marketdirect com au Ph 1300 494 494 44 Hub Assembly...
Page 49: ...www marketdirect com au Ph 1300 494 494 45 Trailing Arm Bushes...
Page 70: ...www marketdirect com au Ph 1300 494 494 66 Trip Name Date Km Start Km Finish Cumulative Km...