www.marketdirect.com.au
Ph: 1300 494 494
42
UltraRapid switched off. Please ensure that it is secure and has locked into place (risk of accident). Defective cowl
caps must not be used. Drain the water heater if there is a risk of frost! Warranty claims will not be accepted if this is
ignored.
Red Indicator Lamp “Fault”
The red indictor lamp (a) lights up if there is a fault. For possible causes please refer to “Fault finding” on page 6.
To unlock, switch off the appliance, wait 10 minutes, and switch on again.
Maintenance
Do not modify this appliance
Servicing should only be carried out by authorised personnel.
Only original Truma parts may be used for maintenance and repair work!
Please contact the Service Australia for service and repairs.
Decalcification
The Truma UltraRapid must be descaled on a regular basis (at least twice a year).
We recommend the use of suitable normal commercial products for the cleaning, disinfection and care of the Truma
UltraRapid. Products containing chlorine are unsuitable.
•
In order to avoid the colonization of micro-organisms, heat up the Truma UltraRapid to 70 °C at
regular intervals.
•
The drain valve (Fig. 2 - 3) and the P&T safety valve (Fig. 2 - 4) are to be operated regularly to remove lime
deposits and to ensure that they are not blocked. Frequency: every 6 month.
Fuses
The water heater 12 V fuse is on the PCB on the water heater.
Important note
Only replace the miniature fuse on the PCB with a fuse of the same type: 1.6 A (slow action).
Circuit Breaker
There is a circuit breaker allocated to the water heater circuit switch on the main electrical panel. To reset this
breaker, push in.
Summary of Contents for XT14E 2021
Page 37: ...www marketdirect com au Ph 1300 494 494 33 ...
Page 40: ...www marketdirect com au Ph 1300 494 494 36 12 Volt Main Circuit Diagram ...
Page 41: ...www marketdirect com au Ph 1300 494 494 37 12 Volt Switch Circuit ...
Page 51: ...www marketdirect com au Ph 1300 494 494 47 Schematic ...
Page 59: ...www marketdirect com au Ph 1300 494 494 55 Trouble Shooting Electrical ...
Page 69: ...www marketdirect com au Ph 1300 494 494 65 Trip Name Date Km Start Km Finish Cumulative Km ...
Page 71: ...www marketdirect com au Ph 1300 494 494 67 Hub Assembly ...
Page 72: ...www marketdirect com au Ph 1300 494 494 68 Trailing Arm Bushes ...