Heater Control
The control switch panel is used to control the unit functions.
1.
Ventilation mode indicator
2.
Heating/Combustion mode indicator
3.
Heating selector button
4.
Stop button
5.
Ventilation selector button
6.
Temperature selector
Important tips about operation
•
Do safety check before initial starting of the heater. Check all components for secure fit (tighten screws where
necessary). Carry out a visual check whether fuel system, combustion air system, exhaust
system is unobstructed.
•
Normal operation of heater at altitudes up to 1500 m.
•
Heater can be used for short periods at altitude 1500 - 3000m. Over 3000m, the heater must be customized.
•
During the initial start-up of the heater, odours can be produced for a short time. This is fully normal during
the first few minutes of operation and does not indicate a malfunction in the heater.
•
During the initial start-up of the heater, there may be an alarm caused by ignition failure. This is because fuel is
needed to fill in fuel pipe. Restarting heater nominally should rectify this.
Operating instructions
•
Pressing ventilation button on switch will activate the fan only. This will operate without combustion to
ventilate the area.
•
Pressing the heating selector button will start the combustion process and begin heating mode. Combustion
and ventilation lamps light up simultaneously.
•
As a fault occurs during operation of the heater, combustion indicator light flashes to indicate cause
of the malfunction.
•
Pressing the stop button. The heater stops working (combustion or ventilation). After delayed stop, the light
goes out.
•
Temperature regulating knob is used for setting temperature for the heater’s automatic temperature control.
Adjustment range is 10-30 ° C.
•
Switch between ventilation and combustion state is possible.
•
When switching off from heating mode, allow the unit to run on ventilation mode until the unit cools. This will
prevent fumes.
Switching on
•
Press heating mode button on control switch, combustion and ventilation indicating light lights up. Then,
heater starts running with glow plug working and fan running at low speed.
•
If there is still too much residual heat in the heat exchanger from when the heater was last used, firstly only the
fan starts up (cold blowing). Once the residual heat has been cleared, the heater starts.
Summary of Contents for XT14E 2021
Page 37: ...www marketdirect com au Ph 1300 494 494 33 ...
Page 40: ...www marketdirect com au Ph 1300 494 494 36 12 Volt Main Circuit Diagram ...
Page 41: ...www marketdirect com au Ph 1300 494 494 37 12 Volt Switch Circuit ...
Page 51: ...www marketdirect com au Ph 1300 494 494 47 Schematic ...
Page 59: ...www marketdirect com au Ph 1300 494 494 55 Trouble Shooting Electrical ...
Page 69: ...www marketdirect com au Ph 1300 494 494 65 Trip Name Date Km Start Km Finish Cumulative Km ...
Page 71: ...www marketdirect com au Ph 1300 494 494 67 Hub Assembly ...
Page 72: ...www marketdirect com au Ph 1300 494 494 68 Trailing Arm Bushes ...