www.marketdirect.com.au
Ph: 1300 494 494
50
Heating process
•
After approx. 60 seconds the fuel supply starts and the fuel / air mixture in the combustion chamber ignites.
•
After the flame sensor has detected the flame, the glow plug is switched off after approx. 90 sec. The heater
has reached the “POWER” stage gradually (maximum fuel quantity, maximum fan speed).
Temperature control
•
The control can be used to pre-set an interior temperature. According to the size of heating space and
prevailing outdoor temperature, the heater’s temperature can be set within the range of +10 °C to +30 °C.
Control in the heating mode
•
During the heating mode, the room temperature or the temperature of the sucked in heating air is constantly
measured. Based on these and the pre-set temperature by controller switch, heater’s working condition will
be adjusted. If the temperature is higher than the temperature selected on the control element, the heater
starts to regulate its output.
•
There are 4 control stages so that the outflow of heat produced by the heater can be adjusted finely to the
heating requirements. Fan speed and fuel quantity correspond to the control stage.
Ventilating mode
•
Press the ventilation button. Heater will work in ventilation mode. Changeover in mode of ventilation and
burning can be initiated at any time.
Switching off
•
Press the stop working button. Heater switches off, metering pump stops working, and glow plug is switched
on for approx. 40 seconds. After fan runs on for approx. 4 minutes to cool down, heater is shut down when
indicating light goes out.
Trouble shooting and fault guide
Code of
malfunction
Description
Flash frequency
1
Circulation of five short flash, one long flash
––––– — –––––
2
Circulation of five short flash, two long flash
––––– —— –––––
3
Circulation of five short flash, three long flash
––––– ——— –––––
4
Circulation of five short flash, four long flash
––––– ———— –––––
5
Circulation of five short flash, five long flash
––––– ————— –––––
6
Circulation of five short flash, six long flash
––––– —————— –––––
7
Circulation of five short flash, seven long flash
––––– ——————— –––––
8
Circulation of five short flash, eight long flash
––––– ———————— –––––
9
Circulation of five short flash, nine long flash
––––– ————————— –––––
10
Circulation of five short flash, ten long flash
––––– —————————— –––––
Summary of Contents for XT14E 2021
Page 37: ...www marketdirect com au Ph 1300 494 494 33 ...
Page 40: ...www marketdirect com au Ph 1300 494 494 36 12 Volt Main Circuit Diagram ...
Page 41: ...www marketdirect com au Ph 1300 494 494 37 12 Volt Switch Circuit ...
Page 51: ...www marketdirect com au Ph 1300 494 494 47 Schematic ...
Page 59: ...www marketdirect com au Ph 1300 494 494 55 Trouble Shooting Electrical ...
Page 69: ...www marketdirect com au Ph 1300 494 494 65 Trip Name Date Km Start Km Finish Cumulative Km ...
Page 71: ...www marketdirect com au Ph 1300 494 494 67 Hub Assembly ...
Page 72: ...www marketdirect com au Ph 1300 494 494 68 Trailing Arm Bushes ...