the installation and operating instructions will void the warranty and release Truma from any liability
claims. It also becomes illegal to use the appliance, and in some countries, this even makes it illegal to
use the vehicle.
•
Any work involving connection or interconnecting wiring must be carried out by a licensed electrician. If
the mains cable (supply cord) is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a hazard.
•
Before accessing terminals, please ensure all supply circuits are disconnected (i.e. 230 V – 240 V and 12 V)
and that the gas supply is securely turned off.
•
The operating pressure for the gas supply is 2.75 kPa (AUS – Propane) and must correspond to the
operating pressure of the appliance (see data plate).
•
LPG systems and pressure regulators must comply with the technical and administrative regulations of
the country in which the appliance is used. For your own safety it is absolutely necessary to have the
complete gas installation regularly checked by an expert (at least every 2 years). The vehicle owner is
always responsible for arranging the gas inspection.
•
Do not operate when travelling.
•
Do not operate the water heater when refueling the vehicle and when it is in the garage.
•
Items sensitive to heat (e. g. spray cans) must not be stored in the installation area, since excess
temperatures may occur there under certain circumstances.
•
During the initial operation of a brand-new appliance (or after it has not been used for some time), an
amount of fumes and a slight smell may be noticed for a short while.
Always observe the operating instructions prior to starting! The vehicle owner is responsible
for correct operation of the appliance
.
Before using the product for the first time, it is essential to flush the entire water supply through with
clean warm water. Always mount the cowl cap when the water heater is not being operated! Drain the
water heater if there is a risk of frost! Warranty claims will not be accepted for frost damage.
Always remove the cowl cover prior to operating the water heater.
If connecting to a central water supply (rural or city connection) or when using more
powerful pumps, a pressure reducer must be used which prevents pressures of greater than
400 kPa occurring in the Truma UltraRapid.
Filling the Truma UltraRapid with Water
Check that the drain valve (3) and the P&T safety valve (Fig.2a - 4) in the cold water intake are closed.
•
Close drain valve (Fig. 2 - 3). Lever in the “e” position (close).
•
Test lever (Fig. 2a - 4a) of the pressure relief valve (4) must be in the “close” position.
Summary of Contents for XT16-HR East West
Page 45: ...www marketdirect com au IPh 1300 494 494 I Copyright I P a g e 43 ...
Page 54: ...www marketdirect com au IPh 1300 494 494 I Copyright I P a g e 52 Wiring Diagram Switch Panel ...
Page 72: ...www marketdirect com au IPh 1300 494 494 I Copyright I P a g e 70 Fig 1 ...
Page 86: ...www marketdirect com au IPh 1300 494 494 I Copyright I P a g e 84 Hub Assembly ...
Page 87: ...www marketdirect com au IPh 1300 494 494 I Copyright I P a g e 85 Trailing Arm Bushes ...
Page 113: ...www marketdirect com au IPh 1300 494 494 I Copyright I P a g e 111 ...