14.
Click the control tab and switch on the laser next to the scanning box
15.
Initialise the sensor by driving slowly, in a forward direction, for approximately 1
minute
16.
When the INS status indicates the INS is working OK the system is ready for heading
calibration before use (Section 13.1 Calibrating Pitch, Roll and Heading).
Do
not
calibrate pitch and roll as these are factory set and will not
change
.
8.1
Restoring Dynascan factory settings
The following information provides a means of re-setting the system back to the MDL factory
parameters, which were originally programmed into the computer and also how to use the
QINSy restore function.
8.1.1
QINSy restore
There is a facility to restore the MDL factory settings used in QINSy, which will re-set all QINSy
parameters to the original factory settings. You can also create your own restore point for a
particular project.
To utilise this function open the QINSy console and click on Tools then select backup project,
or click on QINSy Backup icon.