Chapter 3 Configuring MX-2100
MX-2100/2104
Installation and Operation Manual
3-12
Setting Configuration Parameters
corresponding module
Installation and Operation Manual
contained in Part II of
this manual.
Configuring the SP Parameters
For a list of the SP parameters, refer to Appendix E, Configuration Parameters. You
must always configure the supervisory port parameters locally, irrespective of the
use of downloading.
•
SPEED
- Select AUTO whenever feasible. In this case, start the communication
by pressing <ENTER> three times, to ensure positive identification of terminal
data rate.
The automatic baud rate recognition procedure should be repeated after the DTR
line in the SP connector had been switched to OFF and then ON again.
•
DATA
- Select the required number of data bits (same as on the terminal).
•
PARITY
- Select the required parity (same as on the terminal).
−
Select DCE when directly connected to the supervision terminal. In this
case, you need a straight cable.
−
Select DTE when connected to a modem. In this case, use a cross-over
cable for connection to the modem.
•
MANAGEMENT
- Select YES when the MX-2100 will be managed by an
SNMP network management station. Select NO in any other case.
Note