Appendix B Alarms
MX-2100/2104
Installation and Operation Manual
B-4
Alarm Messages
Table B-1. LCD Alarm Messages (Cont.)
Code Message - LCD
Message - Terminal
Alarm
Type
Description
28
PSWRD DW IS ON
PSWRD SWITCH IS ON Event
The PSWRD switch of the KCL module
is ON. This enforces the default
password
29
SP-PAR DW IS ON
SP-PAR SWITCH IS ON Event
The SP-PARM switch of the KCL module
is ON. This enforces the default
supervisory port parameters
30
DB-INIT DW IS ON DB-INIT SWITCH IS ON Event
The DB-INIT switch of the KCL module
is ON. This will result in the loading of
the default data base parameters when
the MX-2100 will be turned on or reset
31
RTC BATTERY FAIL
REAL TIME CLOCK
BATTERY FAILURE
Event
The voltage of the battery that provides
power to the internal real time clock is
too low for proper operation and must
be replaced as soon as possible. The
battery test is performed during the
power-up test only
32
VOICE S.LOS
VOICE SYNC LOSS, CH State
The channel specified by j (1 or 2) of the
voice module installed in the I/O slot
specified by i (1 through 12) of the local
MX-2100 unit lost synchronization
33
MODEM LOOP
TAIL-END MODEM ON
LOOP, CH
State
The tail-end modem connected to the
channel specified by j (1 or 2) of the
KLS.1 module installed in the I/O slot
specified by i (1 through 12) of the local
MX-2100 unit reports a loop
34
CSU LBK
CSU LBK, SLOT i
State
The KML.6 module installed in slot
(ML-A, ML-B) performs a CSU loopback
in response to a network loopback
request
35
IDLE SEQ
IDLE SEQUENCE,
SLOT i
State
The KML.6 module installed in slot
(ML-A, ML-B) reports the recognition of
an idle code in the data received from
the network
36
OUT OF SERV
ML OUT OF SERVICE,
SLOT i
State
The KML.6 module installed in slot
(ML-A, ML-B) reports the recognition of
an out-of-service code in the data
received from the network
37
OUT FRAME
ML OUT OF FRAME,
SLOT i
State
The KML.6 module installed in slot
(ML-A, ML-B) reports the recognition of
an out-of-frame code in the data
received from the network